SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-165181"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-165181" > Heparin-coated circ...

Heparin-coated circuits reduce activation of granulocytes during cardiopulmonary bypass : A clinical study

Borowiec, Jan (författare)
Uppsala universitet,Thoraxkirurgi
Thelin, Stefan (författare)
Uppsala universitet,Thoraxkirurgi
Bagge, L (författare)
visa fler...
Nilsson, L (författare)
Venge, P (författare)
Hansson, H E (författare)
visa färre...
 (creator_code:org_t)
1992
1992
Engelska.
Ingår i: Journal of Thoracic and Cardiovascular Surgery. - 0022-5223 .- 1097-685X. ; 104:3, s. 642-647
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Activated granulocytes release highly active enzymes such as myeloperoxidase and lactoferrin, which can be involved in tissue destruction mediated by oxygen free radicals. Cardiopulmonary bypass has been reported to activate granulocytes. Bypass circuits coated with heparin have been shown to reduce release of granulocyte factors in experimental studies. In the present study, heparin-coated circuits were compared with noncoated circuits. In seven patients undergoing coronary bypass, heparin-coated circuits were used (group HC), and seven served as control patients (group C). In group HC the heparin dose was reduced to 75% (225 IU/kg). Group C had the standard dose of 300 IU/kg. No preoperative differences in myeloperoxidase and lactoferrin were observed between the groups. At the end of bypass in both groups, there was a significant increase of these enzymes (p less than 0.001) followed by a later decrease. In group HC, however, the release of myeloperoxidase was significantly lower than in group C (215 +/- 24 versus 573 +/- 133 micrograms/L, mean +/- standard error of the mean). The release of lactoferrin was significantly lower in group HC than in group C both at the end of cardiopulmonary bypass (659 +/- 79 versus 1448 +/- 121 micrograms/L) and 3 hours after bypass (224 +/- 37 versus 536 +/- 82 micrograms/L). Granulocytes as well as total number of leukocytes continued to increase until 1 hour after bypass (p less than 0.001) and then manifested a slow decrease. It was concluded that the use of heparin-coated circuits reduced the release of granulocyte factors because of lower activation of leukocytes.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy