Sökning: onr:"swepub:oai:DiVA.org:uu-188728" >
A modified Glenn sh...
A modified Glenn shunt improves haemodynamics in acute right ventricular failure in an experimental model
-
- Vikholm, Per (författare)
- Uppsala universitet,Thoraxkirurgi
-
- Schiller, Petter (författare)
- Uppsala universitet,Thoraxkirurgi
-
- Johansson, Jakob (författare)
- Uppsala universitet,Anestesiologi och intensivvård
-
visa fler...
-
- Hellgren, Laila (författare)
- Uppsala universitet,Thoraxkirurgi
-
visa färre...
-
(creator_code:org_t)
- 2012-07-03
- 2013
- Engelska.
-
Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940 .- 1873-734X. ; 43:3, s. 612-618
- Relaterad länk:
-
https://academic.oup...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVES:Right heart failure is a major cause of morbidity and mortality after left ventricular assist device implantation and is still hard to predict. This study investigated the haemodynamic effect of a modified Glenn shunt on induced right ventricular (RV) failure.METHODS:Isolated RV failure was induced by coronary ligation in 11 pigs. A modified Glenn shunt was established by a superior vena cava to pulmonary artery connection. Haemodynamic data were obtained at baseline, RV failure, and RV failure and open shunt. Myocardial biopsies were taken to ascertain established heart failure.RESULTS:RV failure defined as right atrial pressure ≥20 mmHg was achieved in all 11 animals. A reduction in cardiac output (CO) from 3.7 (3.5-4.2) to 2.3 l/min (2.0-2.6) and mean arterial pressure (MAP) from median 72.7 (70.1-82.2) to 55.9 mmHg (52.6-59.8) was seen during heart failure. The median flow in the shunt was 681 ml. Right atrial pressures decreased from 20.3 (19.6-21.1) to 13.4 mmHg (12.7-14.0), and RV pressures decreased from 18.1 (16.4-20.1) to 13.6 mmHg (13.5-14.2) with open shunt (P = 0.001 for both). CO increased to 2.9 l/min (2.4-3.3) when the shunt was in use. Mixed venous oxygen saturation increased with the shunt from 32 (27-38) to 49% (45-56), P = 0.001. Genes associated with heart failure were upregulated during heart failure.CONCLUSIONS:A modified Glenn shunt improved haemodynamics by reduced right atrial pressure, increased CO, MAP and mixed venous oxygen saturation in an experimental model of induced RV failure.
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas