SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Knaapen P.)
 

Search: WFRF:(Knaapen P.) > Hybrid imaging usin...

Hybrid imaging using quantitative H2 15O PET and CT-based coronary angiography for the detection of coronary artery disease

Danad, I. (author)
Raijmakers, P. G. (author)
Appelman, Y. E. (author)
show more...
Harms, H. J. (author)
De Haan, S. (author)
Van Den Oever, M. L. P. (author)
Heymans, M. W. (author)
Tulevski, I. I. (author)
Van Kuijk, C. (author)
Hoekstra, O. S. (author)
Lammertsma, A. A. (author)
Lubberink, Mark (author)
Uppsala universitet,Enheten för nuklearmedicin och PET
Van Rossum, A. C. (author)
Knaapen, P. (author)
show less...
 (creator_code:org_t)
2012-12-11
2013
English.
In: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 54:1, s. 55-63
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Hybrid imaging using PET in conjunction with CT-based coronary angiography (PET/CTCA) enables near-simultaneous quantification of myocardial blood flow (MBF) and anatomical evaluation of coronary arteries. CTCA is an excellent imaging modality to rule out obstructive coronary artery disease (CAD), but functional assessment is warranted in the presence of a CTCA-observed stenosis because the specificity of CTCA is relatively low. Quantitative H 2 15O PET/CTCA may yield complementary information and enhance diagnostic accuracy. The purpose of this study was to evaluate the diagnostic accuracy of quantitative H2 15O PET/CTCA in a clinical cohort of patients with suspected CAD who underwent both cardiac H 2 15O PET/CTCA and invasive coronary angiography (ICA). In addition, this study aimed to evaluate and compare the accuracy of hyperemic MBF versus coronary flow reserve (CFR). Methods: Patients (n = 120; mean age ± SD, 61 ± 10 y; 77 men and 43 women) with a predominantly intermediate pretest likelihood for CAD underwent both quantitative H 2 15O PET/CTCA and ICA. A ≥50% stenosis at ICA or a fractional flow reserve ≤ 0.80 was considered significant. Results: Obstructive CAD was diagnosed in 49 of 120 patients (41%). The diagnostic accuracy of hyperemic MBF was significantly higher than CFR (80% vs. 68%, respectively, P = 0.02), with optimal cutoff values of 1.86 mL/min/g and 2.30, respectively. On a per-patient basis, the sensitivity, specificity, negative predictive value, and positive predictive value of CTCA were 100%, 34%, 100%, and 51%, respectively, as compared with 76%, 83%, 83%, and 76%, respectively, for quantitative hyperemic MBF PET. Quantitative H2 15O PET/CTCA reduced the number of false-positive CTCA studies from 47 to 6, although 12 of 49 true-positive CTCAs were incorrectly reclassified as false-negative hybrid scans on the basis of (presumably) sufficient hyperemic MBF. Compared with CTCA (61%) or H2 15O PET (80%) alone (both P < 0.05), the hybrid approach significantly improved diagnostic accuracy (85%). Conclusion: The diagnostic accuracy of quantitative H 2 15O PET/CTCA is superior to either H2 15O PET or CTCA alone for the detection of clinically significant CAD. Hyperemic MBF was more accurate than CFR, implying that a single measurement of MBF in diagnostic protocols may suffice.

Keyword

Cardiac hybrid H2 15O PET/CT
Coronary artery disease
Coronary flow reserve
Diagnostic accuracy
Hyperemic MBF

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view