Sökning: onr:"swepub:oai:DiVA.org:uu-211570" >
Total Monte Carlo e...
Total Monte Carlo evaluation for dose calculations
-
- Sjöstrand, Henrik (författare)
- Uppsala universitet,Tillämpad kärnfysik,Nuclear Reactions Group
-
- Alhassan, Erwin (författare)
- Uppsala universitet,Tillämpad kärnfysik,Nuclear Research Group
-
- Conroy, Sean (författare)
- Uppsala universitet,Tillämpad kärnfysik
-
visa fler...
-
- Duan, Junfeng (författare)
- Uppsala universitet,Tillämpad kärnfysik,Nuclear Reactions Group
-
- Hellesen, Carl (författare)
- Uppsala universitet,Tillämpad kärnfysik
-
- Pomp, Stephan (författare)
- Uppsala universitet,Tillämpad kärnfysik,Nuclear Reactions Group
-
- Österlund, Michael (författare)
- Uppsala universitet,Tillämpad kärnfysik,Nuclear Reaction Group
-
- Arjan, Koning J. (författare)
- Uppsala universitet,Tillämpad kärnfysik,Nuclear Research and Consultancy Group
-
- Dimitri, Rochman (författare)
- Nuclear Research and Consultancy Group
-
visa färre...
-
(creator_code:org_t)
- 2013-11-24
- 2014
- Engelska.
-
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 161:1-4, s. 312-315
- Relaterad länk:
-
http://rpd.oxfordjou...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Total Monte Carlo (TMC) is a method to propagate nuclear data (ND) uncertainties in transport codes, by using a large set of ND files, which covers the ND uncertainty. The transport code is run multiple times, each time with a unique ND file, and the result is a distribution of the investigated parameter, e.g. dose, where the width of the distribution is interpreted as the uncertainty due to ND. Until recently, this was computer intensive, but with a new development, fast TMC, more applications are accessible. The aim of this work is to test the fast TMC methodology on a dosimetry application and to propagate the 56Fe uncertainties on the predictions of the dose outside a proposed 14-MeV neutron facility. The uncertainty was found to be 4.2 %. This can be considered small; however, this cannot be generalised to all dosimetry applications and so ND uncertainties should routinely be included in most dosimetry modelling.