SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-213823"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-213823" > Reabsorption atelec...

  • Derosa, SavinoUppsala universitet,Hedenstiernalaboratoriet,Anestesiologi och intensivvård (författare)

Reabsorption atelectasis in a porcine model of ARDS : regional and temporal effects of airway closure, oxygen, and distending pressure

  • Artikel/kapitelEngelska2013

Förlag, utgivningsår, omfång ...

  • American Physiological Society,2013
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-213823
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-213823URI
  • https://doi.org/10.1152/japplphysiol.00763.2013DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Little is known about the small airways dysfunction in acute respiratory distress syndrome (ARDS). By computed tomography (CT) imaging in a porcine experimental model of early ARDS, we aimed at studying the location and magnitude of peripheral airway closure and alveolar collapse under high and low distending pressures and high and low inspiratory oxygen fraction (FIO2). Six piglets were mechanically ventilated under anesthesia and muscle relaxation. Four animals underwent saline-washout lung injury, and two served as healthy controls. Beyond the site of assumed airway closure, gas was expected to be trapped in the injured lungs, promoting alveolar collapse. This was tested by ventilation with an FIO2 of 0.25 and 1 in sequence during low and high distending pressures. In the most dependent regions, the gas/tissue ratio of end-expiratory CT, after previous ventilation with FIO2 0.25 low-driving pressure, was significantly higher than after ventilation with FIO2 1; with high-driving pressure, this difference disappeared. Also, significant reduction in poorly aerated tissue and a correlated increase in nonaerated tissue in end-expiratory CT with FIO2 1 low-driving pressure were seen. When high-driving pressure was applied or after previous ventilation with FIO2 0.25 and low-driving pressure, this pattern disappeared. The findings suggest that low distending pressures produce widespread dependent airway closure and with high FIO2, subsequent absorption atelectasis. Low FIO2 prevented alveolar collapse during the study period because of slow absorption of gas behind closed airways.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Borges, João BatistaUppsala universitet,Hedenstiernalaboratoriet,Klinisk fysiologi(Swepub:uu)joaba230 (författare)
  • Segelsjö, MonicaUppsala universitet,Enheten för radiologi (författare)
  • Tannoia, Angela (författare)
  • Pellegrini, Mariangela (författare)
  • Larsson, AndersUppsala universitet,Hedenstiernalaboratoriet,Anestesiologi och intensivvård(Swepub:uu)andla606 (författare)
  • Perchiazzi, Gaetano (författare)
  • Hedenstierna, GöranUppsala universitet,Klinisk fysiologi,Hedenstiernalaboratoriet(Swepub:uu)goranhed (författare)
  • Uppsala universitetHedenstiernalaboratoriet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of applied physiology: American Physiological Society115:10, s. 1464-14738750-75871522-1601

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy