SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Lammertsma Adriaan A.)
 

Search: WFRF:(Lammertsma Adriaan A.) > Parametric Methods ...

Parametric Methods for Dynamic (11)C-Phenytoin PET Studies.

Mansor, Syahir (author)
Yaqub, Maqsood (author)
Boellaard, Ronald (author)
show more...
Froklage, Femke E (author)
de Vries, Anke (author)
Bakker, Esther D M (author)
Voskuyl, Rob A (author)
Eriksson, Jonas (author)
Uppsala universitet,Avdelningen för Molekylär Avbildning
Schwarte, Lothar A (author)
Verbeek, Joost (author)
Windhorst, Albert D (author)
Lammertsma, Adriaan A (author)
show less...
 (creator_code:org_t)
2016-09-22
2017
English.
In: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 58:3, s. 479-483
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • In this study, the performance of various methods for generating quantitative parametric images of dynamic (11)C-phenytoin PET studies was evaluated. Methods: Double-baseline 60-min dynamic (11)C-phenytoin PET studies, including online arterial sampling, were acquired for 6 healthy subjects. Parametric images were generated using Logan plot analysis, a basis function method, and spectral analysis. Parametric distribution volume (VT) and influx rate (K1) were compared with those obtained from nonlinear regression analysis of time-activity curves. In addition, global and regional test-retest (TRT) variability was determined for parametric K1 and VT values. Results: Biases in VT observed with all parametric methods were less than 5%. For K1, spectral analysis showed a negative bias of 16%. The mean TRT variabilities of VT and K1 were less than 10% for all methods. Shortening the scan duration to 45 min provided similar VT and K1 with comparable TRT performance compared with 60-min data. Conclusion: Among the various parametric methods tested, the basis function method provided parametric VT and K1 values with the least bias compared with nonlinear regression data and showed TRT variabilities lower than 5%, also for smaller volume-of-interest sizes (i.e., higher noise levels) and shorter scan duration.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

11C-phenytoin
PET quantification
parametric kinetic modeling
test-retest variability

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view