SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-343660"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-343660" > Fenestrated TEVAR U...

Fenestrated TEVAR Using a Guidewire Fixator for Anchoring in Aortic Arch Target Vessels

Koelbel, Tilo (författare)
Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
Bosaeus, Linus (författare)
Endovasc Dev AB, Uppsala, Sweden.
Tsilimparis, Nikolaos (författare)
Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
visa fler...
Heidemann, Franziska (författare)
Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
Rohlffs, Fiona (författare)
Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
Liungman, Krister (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
visa färre...
Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany Endovasc Dev AB, Uppsala, Sweden. (creator_code:org_t)
2017-11-29
2018
Engelska.
Ingår i: Journal of Endovascular Therapy. - : SAGE Publications. - 1526-6028 .- 1545-1550. ; 25:1, s. 40-46
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose:To report a new facilitated method for securing target vessel access during single fenestrated and branched thoracic endovascular repair using a guidewire fixator.Technique: The Liungman Guidewire Fixator (LGF) includes a 0.035-inch guidewire that is fitted with a stopper close to the distal end and a self-expanding anchoring element that is freely movable over the guidewire to the point of the stopper. The technique of using a LGF for anchoring in a target vessel is described in a 75-year-old woman with a 53-mm saccular arch aneurysm. She was treated with a fenestrated Zenith stent-graft that had a catheter-preloaded fenestration for the left subclavian artery (LSA) and a scallop for the left common carotid artery. To avoid through-and-through wire and brachial access, the LGF was used to secure the guidewire in the LSA during stent-graft deployment.Conclusion: The use of an LGF for anchoring in the target LSA during fenestrated arch endografting was feasible and safe.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

aortic aneurysm
aortic arch
fenestrated stent-graft
guidewire fixator
left subclavian artery
thoracic aorta
thoracic endovascular aortic repair

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy