SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-375802"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-375802" > Test-retest variabi...

  • Schoffelen, Paul F. M.Maastricht Univ, Med Ctr, NUTRIM Sch Nutr Toxicol & Metab, Dept Human Biol, Maastricht, Netherlands;Maastricht Univ, Med Ctr, NUTRIM Sch Nutr Toxicol & Metab, Dept Nutr & Movement Sci, Maastricht, Netherlands (författare)

Test-retest variability of VO2max using total-capture indirect calorimetry reveals linear relationship of VO2 and Power

  • Artikel/kapitelEngelska2019

Förlag, utgivningsår, omfång ...

  • 2018-11-12
  • Wiley,2019
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-375802
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-375802URI
  • https://doi.org/10.1111/sms.13324DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • This study aimed to analyze the intra-individual variation in VO2max of human subjects using total-capture and free-flow indirect calorimetry. Twenty-seven men (27 ± 5 year; VO2max 49-79 mL•kg-1 •min-1) performed two maximal exertion tests (CPETs) on a cycle ergometer, separated by a 7 ± 2 day interval. VO2 and VCO2 were assessed using an indirect calorimeter (Omnical) with total capture of exhalation in a free-flow airstream. Thirteen subjects performed a third maximal exertion test using a breath-by-breath calorimeter (Oxycon Pro). On-site validation was deemed a requirement. For the Omnical, the mean within-subject CV for VO2max was 1.2 ± 0.9% (0.0%-4.4%) and for ergometer workload P max 1.3 ± 1.3% (0%-4.6%). VO2max values with the Oxycon Pro were significantly lower in comparison with Omnical (P< t 0.001; t test) with mean 3570 vs 4061 and difference SD 361 mL • min-1. Validation results for the Omnical with methanol combustion were -0.05 ± 0.70% (mean ± SD; n = 31) at the 225 mL • min-1 VO2 level and -0.23 ± 0.80% (n = 31) at the 150 mL • min-1 VCO2 level. Results using gas infusion were 0.04 ± 0.75% (n = 34) and -0.99 ± 1.05% (n = 24) over the respective 500-6000 mL • min-1 VO2 and VCO2 ranges. Validation results for the Oxycon Pro in breath-by-breath mode were - 2.2 ± 1.6% (n = 12) for VO2 and 5.7 ± 3.3% (n = 12) for VCO2 over the 1000-4000 mL •min-1 range. On a Visual analog scale, participants reported improved breathing using the free-flow indirect calorimetry (score 7.6 ± 1.2 vs 5.1 ± 2.7, P = 0.008). We conclude that total capturing free-flow indirect calorimetry is suitable for measuring VO2 even with the highest range. VO2max was linear with the incline in P max over the full range.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • den Hoed, MarcelUppsala universitet,Medicinsk genetik och genomik,Science for Life Laboratory, SciLifeLab(Swepub:uu)marde358 (författare)
  • van Breda, EricUniv Antwerp, Dept Rehabil Sci & Physiotherapy, MOVANT, Fac Med & Hlth Sci, Antwerp, Belgium (författare)
  • Plasqui, GuyMaastricht Univ, Med Ctr, NUTRIM Sch Nutr Toxicol & Metab, Dept Nutr & Movement Sci, Maastricht, Netherlands (författare)
  • Maastricht Univ, Med Ctr, NUTRIM Sch Nutr Toxicol & Metab, Dept Human Biol, Maastricht, Netherlands;Maastricht Univ, Med Ctr, NUTRIM Sch Nutr Toxicol & Metab, Dept Nutr & Movement Sci, Maastricht, NetherlandsMedicinsk genetik och genomik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Scandinavian Journal of Medicine and Science in Sports: Wiley29:2, s. 213-2220905-71881600-0838

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Schoffelen, Paul ...
den Hoed, Marcel
van Breda, Eric
Plasqui, Guy
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Idrottsvetenskap
Artiklar i publikationen
Scandinavian Jou ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy