Sökning: onr:"swepub:oai:DiVA.org:uu-418170" > Diagnostic Accuracy...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 04620naa a2200529 4500 | |
001 | oai:DiVA.org:uu-418170 | |
003 | SwePub | |
008 | 200831s2020 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-4181702 URI |
024 | 7 | a https://doi.org/10.1016/j.jcmg.2020.02.0232 DOI |
040 | a (SwePub)uu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Rosengren, Sarau Uppsala universitet,Hematologi4 aut0 (Swepub:uu)sarro118 |
245 | 1 0 | a Diagnostic Accuracy of [11C]PIB Positron Emission Tomography for Detection of Cardiac Amyloidosis |
264 | 1 | b Elsevier BV,c 2020 |
338 | a print2 rdacarrier | |
520 | a OBJECTIVES: This dual-site study evaluated the diagnostic accuracy of the method.BACKGROUND: Pittsburgh compound ([11C]PIB) positron emission tomography (PIB-PET) has shown promise as a specific and noninvasive method for the diagnosis of cardiac amyloidosis (CA).METHODS: The study had 2 parts. In the initial study, 51 subjects were included, 36 patients with known CA and increased wall thickness (15 immunoglobulin light chain [AL] and 21 transthyretin [ATTR] amyloidosis) and 15 control patients (7 were nonamyloid hypertrophic and 8 healthy volunteers). Subjects underwent PIB-PET and echocardiography. Sensitivity and specificity of PIB-PET were established for 2 simple semiquantitative approaches, standardized uptake value ratio (SUVR) and retention index (RI). The second part of the study included 11 amyloidosis patients (5 AL and 6 hereditary ATTR) without increased wall thickness to which the optimal cutoff values of SUVR (>1.09) and RI (>0.037 min-1) were applied prospectively.RESULTS: The diagnostic accuracy of visual inspection of [11C]PIB uptake was 100% in discriminating CA patients with increased wall thickness from controls. Semiquantitative [11C]PIB uptake discriminated CA from controls with a 94% (95% confidence interval [CI]: 80% to 99%) sensitivity for both SUVR and RI and specificity of 93% (95% CI: 66% to 100%) for SUVR and 100% (95% CI: 75% to 100%) for RI. [11C]PIB uptake was significantly higher in AL-CA than in ATTR-CA patients (p < 0.001) and discriminated AL-CA from controls with 100% (95% CI: 88% to 100%) accuracy for both the semiquantitative measures. In the prospective group without increased wall thickness, RI was elevated compared to controls (p = 0.001) and 5 of 11 subjects were evaluated as [11C]PIB PET positive.CONCLUSIONS: In a dual-center setting, [11C]PIB PET was highly accurate in detecting cardiac involvement in the main amyloid subtypes, with 100% accuracy in AL amyloidosis. A proportion of amyloidosis patients without known cardiac involvement were [11C]PIB PET positive, indicating that the method may detect early stages of CA. | |
653 | a PET | |
653 | a Pittsburgh compound B | |
653 | a diagnosis | |
653 | a heart | |
653 | a nuclear imaging | |
700 | 1 | a Skibsted Clemmensen, Tor4 aut |
700 | 1 | a Tolbod, Lars4 aut |
700 | 1 | a Granstam, Sven-Olof,d 1963-u Uppsala universitet,Klinisk fysiologi4 aut0 (Swepub:uu)svolgran |
700 | 1 | a Eiskjær, Hans4 aut |
700 | 1 | a Wikström, Gerhardu Uppsala universitet,Kardiologi4 aut0 (Swepub:uu)gewik021 |
700 | 1 | a Vedin, Olau Uppsala universitet,Kardiologi4 aut0 (Swepub:uu)olved933 |
700 | 1 | a Kero, Tanjau Uppsala universitet,Radiologi4 aut0 (Swepub:uu)tanke311 |
700 | 1 | a Lubberink, Marku Uppsala universitet,Radiologi,Institutionen för immunologi, genetik och patologi4 aut0 (Swepub:uu)marklubb |
700 | 1 | a Harms, Hendrik J4 aut |
700 | 1 | a Flachskampf, Frank A,d 1957-u Uppsala universitet,Klinisk fysiologi4 aut0 (Swepub:uu)frafl698 |
700 | 1 | a Baron, Tomaszu Uppsala universitet,Klinisk fysiologi4 aut0 (Swepub:uu)tomba515 |
700 | 1 | a Carlson, Kristinau Uppsala universitet,Hematologi4 aut0 (Swepub:uu)krica965 |
700 | 1 | a Mikkelsen, Fabian4 aut |
700 | 1 | a Antoni, Gunnaru Uppsala universitet,Preparativ läkemedelskemi4 aut0 (Swepub:uu)gunnarat |
700 | 1 | a Frost Andersen, Niels4 aut |
700 | 1 | a Hvitfeldt Poulsen, Steen4 aut |
700 | 1 | a Sörensen, Jensu Uppsala universitet,Radiologi4 aut0 (Swepub:uu)jenssore |
710 | 2 | a Uppsala universitetb Hematologi4 org |
773 | 0 | t JACC Cardiovascular Imagingd : Elsevier BVg 13:6, s. 1337-1347q 13:6<1337-1347x 1936-878Xx 1876-7591 |
856 | 4 | u https://doi.org/10.1016/j.jcmg.2020.02.023 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-418170 |
856 | 4 8 | u https://doi.org/10.1016/j.jcmg.2020.02.023 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy