SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-429764"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-429764" > Improved sensitivit...

Improved sensitivity in hydrophilic interaction liquid chromatography-electrospray-mass spectrometry after removal of sodium and potassium ions from biological samples

Erngren, Ida, 1989- (författare)
Uppsala universitet,Analytisk farmaceutisk kemi
Nestor, Marika, 1976- (författare)
Uppsala universitet,Medicinsk strålningsvetenskap
Pettersson, Curt (författare)
Uppsala universitet,Analytisk farmaceutisk kemi
visa fler...
Hedeland, Mikael (författare)
Uppsala universitet,Analytisk farmaceutisk kemi
visa färre...
 (creator_code:org_t)
2021-03-15
2021
Engelska.
Ingår i: Metabolites. - : MDPI. - 2218-1989 .- 2218-1989. ; 11:3
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Inorganic ions, such as sodium and potassium, are present in all biological matrices and are sometimes also added during sample preparation. However, these inorganic ions are known to hamper electrospray ionization -mass spectrometry (ESI-MS) applications, especially in hydrophilic interaction liquid chromatography (HILIC) where they are retained and can be detected as adducts and clusters with mobile phase components or analytes. The retention of inorganic ions leads to co-elution with analytes and as a result ion-suppression, extensive adduct formation and problems with reproducibility. In the presented work, a sample preparation method using cation exchange solid phase extraction (SPE) was developed to trap Na+ and K+ ions from human blood plasma and head and neck cancer cells for the analysis of small cationic, anionic as well as neutral organic analytes. The investigated analytes were small, hydrophilic compounds typically in focus in metabolomics studies. The samples were analyzed using full-scan HILIC-ESI-quadrupole time of flight (QTOF)-MS with an untargeted, screening approach. Method performance was evaluated using multivariate data analysis as well as relative quantifications, spiking of standards to evaluate linearity of response and post-column infusion to study ion-suppression. In blood plasma, the reduction of sodium and potassium ion concentration resulted in improved sensitivity increased signal intensity for 19 out of 28 investigated analytes, improved linearity of response, reduced ion-suppression and reduced cluster formation as well as adduct formation. Thus, the presented method has significant potential to improve data quality in metabolomics studies.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

hydrophilic interaction liquid chromatography
mass spectrometry
metabolomics
sample preparation
ion suppression
matrix effects
alkali metal ions
Analytical Pharmaceutical Chemistry
Analytisk farmaceutisk kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Erngren, Ida, 19 ...
Nestor, Marika, ...
Pettersson, Curt
Hedeland, Mikael
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Metabolites
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy