Influence of patient motion on quantitative accuracy in cardiac 15O-water positron emission tomography.
- Artikel/kapitelEngelska2022
Förlag, utgivningsår, omfång ...
-
2021-03-02
-
Springer Nature,2022
-
electronicrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:uu-437381
-
https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-437381URI
-
https://doi.org/10.1007/s12350-021-02550-9DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
BACKGROUND: Patient motion is a common problem during cardiac PET. The purpose of the present study was to investigate to what extent motions influence the quantitative accuracy of cardiac 15O-water PET/CT and to develop a method for automated motion detection.METHOD: Frequency and magnitude of motion was assessed visually using data from 50 clinical 15O-water PET/CT scans. Simulations of 4 types of motions with amplitude of 5 to 20 mm were performed based on data from 10 scans. An automated motion detection algorithm was evaluated on clinical and simulated motion data. MBF and PTF of all simulated scans were compared to the original scan used as reference.RESULTS: Patient motion was detected in 68% of clinical cases by visual inspection. All observed motions were small with amplitudes less than half the LV wall thickness. A clear pattern of motion influence was seen in the simulations with a decrease of myocardial blood flow (MBF) in the region of myocardium to where the motion was directed. The perfusable tissue fraction (PTF) trended in the opposite direction. Global absolute average deviation of MBF was 3.1% ± 1.8% and 7.3% ± 6.3% for motions with maximum amplitudes of 5 and 20 mm, respectively. Automated motion detection showed a sensitivity of 90% for simulated motions ≥ 10 mm but struggled with the smaller (≤ 5 mm) simulated (sensitivity 45%) and clinical motions (accuracy 48%).CONCLUSION: Patient motion can impair the quantitative accuracy of MBF. However, at typically occurring levels of patient motion, effects are similar to or only slightly larger than inter-observer variability, and downstream clinical effects are likely negligible.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Harms, Hendrik J
(författare)
-
Kero, TanjaUppsala universitet,Radiologi(Swepub:uu)tanke311
(författare)
-
Sörensen, JensUppsala universitet,Radiologi,Klinisk fysiologi(Swepub:uu)jenssore
(författare)
-
Lubberink, MarkUppsala universitet,Radiologi,Institutionen för immunologi, genetik och patologi(Swepub:uu)marklubb
(författare)
-
Uppsala universitetRadiologi