SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-447949"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-447949" > The preoperative lo...

The preoperative localisation of small parathyroid adenomas improves when adding Tc-99m-Sestamibi SPECT to multiphase contrast-enhanced CT

Sandqvist, Patricia (författare)
Karolinska Institutet
Farnebo, Jacob (författare)
Karolinska Inst, Dept Mol Med & Surg, Stockholm, Sweden; Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
Nilsson, Inga-Lena (författare)
Karolinska Institutet
visa fler...
Grybäck, Per (författare)
Karolinska Institutet
Sundin, Anders, 1954- (författare)
Uppsala universitet,Radiologi
Sanchez-Crespo, Alejandro (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2021-06-05
2021
Engelska.
Ingår i: Insights into Imaging. - : Springer Science and Business Media LLC. - 1869-4101. ; 12:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ObjectivesTo investigate the incremental value of Sestamibi SPECT combined with a non-enhanced and contrast-enhanced CT, using SPECT/CT, for the preoperative localisation of small parathyroid adenomas (PTA).MethodsRetrospectively, 147 patients surgically cured from primary hyperparathyroidism, as verified by biochemistry 6 months postoperatively, were included. All patients had preoperatively undergone a dual time 99mTechnetium-Sestamibi SPECT (S) with multiphase CT including native (N), arterial (A) and venous (V) phases. Independently, two radiologists blinded from both the surgical and the preoperative imaging reports, sequentially performed PTA localisation starting with either [A] or [V], thereafter [A + N] or [V + N] and finally with the complete [A + N + S] or [V + N + S]. PTA localisation was reported for each image-set. The readers results were combined and the diagnostic performance for each image set was determined. Sensitivity was also calculated for the different quartiles of PTA weight distribution.ResultsThe median adenoma weight was 315 mg. No statistically significant differences in diagnostic performance between arterial and venous based image sets were found. The net effect of adding [N] was to increase specificity. Sestamibi SPECT significantly increased the overall diagnostic accuracy for arterial- and venous-based image sets, p = 0.0008 and p = 0.001, respectively. [A + N + S] was found to have the highest diagnostic performance with 86.5% sensitivity and 94.9% overall accuracy. [A + N + S] was particularly advantageous for locating PTA in the lower weight quartiles.ConclusionsNative CT-phase and dual time point Sestamibi SPECT increase specificity and sensitivity, respectively. These, in combination with a single contrast-enhanced CT-phase is the most optimal examination protocol for preoperative localisation of PTA using SPECT/CT.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Parathyroid adenoma
Single-photon emission-computed tomography
4D computed tomography
Parathyroidectomy
Contrast media

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy