SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-451117"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-451117" > A feature-extractio...

A feature-extraction and pile-up reconstruction algorithm for the forward-spectrometer EMC of the PANDA experiment

Preston, Markus (författare)
Stockholms universitet,Fysikum,Stockholm Univ, Dept Phys, S-10691 Stockholm, Sweden.
Bukreeva, S. (författare)
Inst High Energy Phys, Protvino 142281, Moscow Region, Russia.
Diehl, S. (författare)
Justus Liebig Univ Giessen, Phys Inst 2, D-35392 Giessen, Germany.
visa fler...
Marciniewski, Pawel (författare)
Uppsala universitet,Kärnfysik
Novotny, R. W. (författare)
Justus Liebig Univ Giessen, Phys Inst 2, D-35392 Giessen, Germany.
Ryzhikov, S. (författare)
Inst High Energy Phys, Protvino 142281, Moscow Region, Russia.
Semenov, P. A. (författare)
Inst High Energy Phys, Protvino 142281, Moscow Region, Russia.
Tegnér, Per-Erik (författare)
Stockholms universitet,Fysikum,Stockholm Univ, Dept Phys, S-10691 Stockholm, Sweden.
visa färre...
 (creator_code:org_t)
Elsevier, 2021
2021
Engelska.
Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 1011
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A digital algorithm for real-time feature extraction, i.e. determination of pulse amplitude and timing, has been developed for the forward-spectrometer electromagnetic calorimeter in the PANDA experiment. The algorithm, which is based on the well known optimal-filter algorithm, has been designed to allow reconstruction of pile-up signals in real time and to work in a free-running DAQ system such as PANDA. To benchmark the algorithm, a Geant4-based Monte Carlo model of photon interactions in the calorimeter has been developed to generate realistic detector signals which were used as inputs to a VHDL simulation of the algorithm. The results of this simulation study show that the developed algorithm improves the time resolution by almost 50% compared to a conventional linear constant fraction discriminator algorithm. For the PANDA calorimeter, this results in a time root resolution close to 100 ps/ GeV per detector element at high energies. The algorithm allows reconstruction of the amplitude and timing of pile-up pulses separated by as little as 30 ns with good efficiency, fulfilling the PANDA requirements.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)
NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)
NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

Electromagnetic calorimeter
Sampling ADC
Optimal filter
Feature extraction
Pile-up reconstruction
FPGA

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy