SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-463979"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-463979" > Fat/water separatio...

Fat/water separation in k-space with real-valued estimates and its combination with POCS.

Berglund, Johan (författare)
Karolinska Institutet
Rydén, Henric (författare)
Karolinska Institutet
Avventi, Enrico (författare)
visa fler...
Norbeck, Ola (författare)
Karolinska Institutet
Sprenger, Tim (författare)
Skare, Stefan (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2019-08-16
2020
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 83:2, s. 653-661
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To develop reconstruction methods for improved image quality of chemical shift displacement-corrected fat/water imaging combined with partial Fourier acquisition.THEORY: Fat/water separation in k-space enables correction of chemical shift displacement. Modeling fat and water as real-valued rather than complex improves the conditionality of the inverse problem. This advantage becomes essential for k-space separation. In this work, it was described how to perform regularized fat/water imaging with real estimates in k-space, and how fat/water imaging can be combined with partial Fourier reconstruction using Projection Onto Convex Sets (POCS).METHODS: The reconstruction methods were demonstrated on chemical shift encoded gradient echo and fast spin echo data from volunteers, acquired at 1.5 T and 3 T. Both fully sampled and partial Fourier acquisitions were made. Data was retrospectively rejected from the fully sampled dataset to evaluate POCS and homodyne reconstruction.RESULTS: Fat/water separation in k-space eliminated chemical shift displacement, while real-valued estimates considerably reduced the noise amplification compared to complex estimates. POCS reconstruction could recover high spatial frequency information in the fat and water images with lower reconstruction error than homodyne. Partial Fourier in the readout direction enabled more flexible choice of gradient echo imaging parameters, in particular image resolution.CONCLUSION: Chemical shift displacement-corrected fat/water imaging can be performed with regularization and real-valued estimates to improve image quality by reducing ill-conditioning of the inverse problem in k-space. Fat/water imaging can be combined with POCS, which offers improved image quality over homodyne reconstruction.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Dixon
POCS
artifact correction
chemical shift imaging
fat-water separation
partial Fourier

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy