Influence of image reconstruction on quantitative cardiac 15O-water positron emission tomography
-
- Nordström, Jonny (författare)
- Uppsala universitet,Centrum för klinisk forskning, Gävleborg,Radiologi
-
- Lindström, Elin (författare)
- Uppsala universitet,Radiologi,Medical Physics, Uppsala University Hospital, Uppsala, Sweden
-
- Kero, Tanja (författare)
- Uppsala University Hospital, PET Center
-
visa fler...
-
- Sörensen, Jens (författare)
- Uppsala universitet,Radiologi,PET Center, Uppsala University Hospital, Uppsala, Sweden
-
- Lubberink, Mark (författare)
- Uppsala universitet,Radiologi,Medical Physics, Uppsala University Hospital, Uppsala, Sweden
-
visa färre...
-
(creator_code:org_t)
- 2022-08-04
- 2023
- Engelska.
-
Ingår i: Journal of Nuclear Cardiology. - : Springer Nature. - 1071-3581 .- 1532-6551. ; 30:2, s. 716-725
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://uu.diva-port... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- BackgroundThe impact on quantitative 15O-water PET/CT of a wide range of different reconstruction settings, including regularized reconstruction by block-sequential regularized expectation maximization (BSREM), was investigated.MethodsTwenty clinical stress scans from patients referred for assessment of myocardial ischemia were included. Patients underwent a 4-min dynamic stress PET scan with 15O-water on a digital PET/CT scanner. Twenty-two reconstructions were generated from each scan and a clinical reconstruction was used as reference. Varied parameters were number of iterations, filter, exclusion of time-of-flight and point-spread function, and regularization parameter with BSREM. Analyses were performed in aQuant utilizing two different methods and resulting regional myocardial blood flow (MBF), perfusable tissue fraction (PTF), and transmural MBF (MBFt) values were evaluated.ResultsAcross the two analyses, correlations toward the reference reconstruction were strong for all parameters (ρ ≥ 0.83). Using automated analysis and the diagnostic threshold of hyperemic MBF at 2.3 mL⋅g−1⋅min−1, diagnosis was unchanged irrespective of reconstruction method in all patients except for one, where only four of the most extreme reconstruction methods resulted in a change of diagnosis.ConclusionThe low sensitivity of MBF values to reconstruction method and, as previously shown, scanner type and PET/CT misalignment, confirms that diagnostic hyperemic MBF cutoff values can be consistently used for 15O-water.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- 15O-water
- quantitative PET/CT
- myocardial blood flow
- image reconstruction