Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
- Artikel/kapitelEngelska2022
Förlag, utgivningsår, omfång ...
-
Elsevier,2022
-
electronicrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:uu-487295
-
https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-487295URI
-
https://doi.org/10.1016/j.resplu.2022.100311DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
Introduction: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation.Methods: 16 piglets were anesthetized and randomized into 2 groups. After 3 minutes of induced ventricular fibrillation, a LUCAS 3 device was used to perform chest compressions, in one group a suction cup was mounted on the device's piston, while in the other group, compressions were per -formed by the bare piston. The device was used in 30:2 mode and the animals were manually ventilated. Endpoints of the study were: end tidal carbon dioxide, coronary and cerebral perfusion pressures, and brain oxygenation (measured using near infrared spectroscopy). At the end of the protocol, the animals that got a return to spontaneous circulation were observed for 60 minutes, then euthanized.Results: No difference was found in end tidal carbon dioxide or tidal volumes. Coronary perfusion pressure and cerebral oxygenation were higher in the Suction cup group over the entire experiment time, while cerebral perfusion pressure was higher only in the last 5 minutes of CPR. A passive tidal volume (air going in and out the airways during compressions) was detected and found correlated to end tidal carbon dioxide.Conclusions: The use of a suction cup on a piston-based chest compression device did not increase end tidal carbon dioxide, but it was associated to a higher coronary perfusion pressure.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Smekal, David,1971-Uppsala universitet,Anestesiologi och intensivvård,Uppsala Univ Hosp, Emergency Med Serv EMS, Sjukhusvagen, S-75185 Uppsala, Sweden.(Swepub:uu)davsm531
(författare)
-
Marchesi, SilviaJolife Stryker AB, S-23633 Scheelevagen, Sweden.
(författare)
-
Lipcsey, MiklósUppsala universitet,Hedenstiernalaboratoriet(Swepub:uu)milip123
(författare)
-
Rubertsson, StenUppsala universitet,Anestesiologi och intensivvård(Swepub:uu)stenrube
(författare)
-
Uppsala universitetAnestesiologi och intensivvård
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Resuscitation Plus: Elsevier122666-5204
Internetlänk
Hitta via bibliotek
Till lärosätets databas