Sökning: onr:"swepub:oai:DiVA.org:uu-506987" >
Análisis de la foto...
Análisis de la fotopletismografía para determinación de variaciones en el tono vascular y la presión arterial : Estudio basado en redes neuronales [Photoplethysmography waveform analysis for classification of vascular tone andarterial blood pressure: Study based on neural networks]
-
- Echeverria, N. I. (författare)
- Univ Nacl Mar del Plata, Fac Ingn, Lab Bioingn, ICYTE CONICET, Mar Del Plata, Buenos Aires, Argentina.
-
- Scandurra, A. G. (författare)
- Univ Nacl Mar del Plata, Fac Ingn, Lab Bioingn, ICYTE CONICET, Mar Del Plata, Buenos Aires, Argentina.
-
- Acosta, C. M. (författare)
- Hosp Privado Comun, Dept Anestesiol, Mar Del Plata, Buenos Aires, Argentina.
-
visa fler...
-
Meschino, G. J. (författare)
-
- Suarez-Sipmann, Fernando (författare)
- Uppsala universitet,Klinisk fysiologi,Hedenstiernalaboratoriet,Ctr Invest Biomed Red Enfermedades Resp CIBERES, Madrid, Spain.;Hosp Univ Princesa, Dept Cuidados Crit, Madrid, Spain.
-
- Tusman, G. (författare)
- Hosp Privado Comun, Dept Anestesiol, Mar Del Plata, Buenos Aires, Argentina.
-
visa färre...
-
Univ Nacl Mar del Plata, Fac Ingn, Lab Bioingn, ICYTE CONICET, Mar Del Plata, Buenos Aires, Argentina Hosp Privado Comun, Dept Anestesiol, Mar Del Plata, Buenos Aires, Argentina. (creator_code:org_t)
- Elsevier BV, 2023
- 2023
- Engelska.
-
Ingår i: REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION. - : Elsevier BV. - 0034-9356 .- 2340-3284. ; 70:4, s. 209-217
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: To test whether a Shallow Neural Network (S-NN) can detect and classify vasculartone dependent changes in arterial blood pressure (ABP) by advanced photopletysmographic(PPG) waveform analysis.Methods: PPG and invasive ABP signals were recorded in 26 patients undergoing scheduled general surgery. We studied the occurrence of episodes of hypertension (systolic arterial pressure(SAP) > 140 mmHg), normotension and hypotension (SAP < 90 mmHg). Vascular tone accordingto PPG was classified in two ways: 1) By visual inspection of changes in PPG waveform amplitude and dichrotic notch position; where Classes I-II represent vasoconstriction (notch placed> 50% of PPG amplitude in small amplitude waves), Class III normal vascular tone (notch placedbetween 20-50% of PPG amplitude in normal waves) and Classes IV-V-VI vasodilation (notch <20% of PPG amplitude in large waves). 2) By an automated analysis, using S-NN trained andvalidated system that combines seven PPG derived parameters.Results: The visual assessment was precise in detecting hypotension (sensitivity 91%, specificity86% and accuracy 88%) and hypertension (sensitivity 93%, specificity 88% and accuracy 90%). Normotension presented as a visual Class III (III-III) (median and 1st-3rdquartiles), hypotensionas a Class V (IV-VI) and hypertension as a Class II (I-III); all p < 0.0001. The automated S-NNperformed well in classifying ABP conditions. The percentage of data with correct classificationby S-ANN was 83% for normotension, 94% for hypotension, and 90% for hypertension.Conclusions: Changes in ABP were correctly classified automatically by S-NN analysis of the PPGwaveform contour.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- Arterial blood pressure
- Photoplethysmography
- Vascular tone
- Arterial compliance
- Neural networks
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas