SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-533631"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-533631" > Patterns of practic...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003986naa a2200541 4500
001oai:DiVA.org:uu-533631
003SwePub
008240627s2024 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-5336312 URI
024a https://doi.org/10.1016/j.ejmp.2024.1034072 DOI
040 a (SwePub)uu
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Trnková, Petra4 aut
2451 0a Patterns of practice of image guided particle therapy for cranio-spinal irradiation :b A site specific multi-institutional survey of European Particle Therapy Network
264 1b Elsevier,c 2024
338 a electronic2 rdacarrier
520 a PurposeTo investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI).MethodsA multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice. The centres participating in the institutional survey were invited to join the Delphi process.ResultsEleven centres participated in the survey. Imaging for treatment planning was rather similar among the centres with Computed Tomography (CT) being the main modality. For positioning verification, 2D IGPT was more commonly used than 3D IGPT. Two centres performed routinely imaging for plan adaptation, by the rest ad hoc. Eight centres participated in the Delphi consensus analysis. The full consensus was reached on the use of CT imaging without contrast for treatment planning and the role of magnetic resonance imaging (MRI) in target and organs-at-risk delineation. There was an agreement on the necessity to perform patient position verification and correction before each isocentre. The most important outcome was the clear need for standardization and harmonization of the workflow.ConclusionThere were differences in CSI IGPT clinical practice among the European particle therapy centres. Moreover, the optimal workflow as identified by experts was not yet reached. There is a strong need for consensus guidelines. The state-of-the-art imaging technology and protocols need to be implemented into clinical practice to improve the quality of IGPT for CSI.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Cancer och onkologi0 (SwePub)302032 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Cancer and Oncology0 (SwePub)302032 hsv//eng
700a Dasu, Alexandru,d 1972-u Uppsala universitet,Institutionen för immunologi, genetik och patologi4 aut0 (Swepub:uu)aleda511
700a Placidi, Lorenzo4 aut
700a Stock, Markus4 aut
700a Toma-Dasu, Iuliana4 aut
700a Brouwer, Charlotte L.4 aut
700a Gosling, Andrew4 aut
700a Jouglar, Emmanuel4 aut
700a Kristensen, Ingrid4 aut
700a Martin, Valentine4 aut
700a Moinuddin, Syed4 aut
700a Pasquie, Isabelle4 aut
700a Peters, Sarah4 aut
700a Pica, Alessia4 aut
700a Plaude, Sandija4 aut
700a Righetto, Roberto4 aut
700a Rombi, Barbara4 aut
700a Thariat, Juliette4 aut
700a van der Weide, Hiske4 aut
700a Hoffmann, Aswin4 aut
700a Bolsi, Alessandra4 aut
710a Uppsala universitetb Institutionen för immunologi, genetik och patologi4 org
773t Physica medica (Testo stampato)d : Elsevierg 123q 123x 1120-1797x 1724-191X
856u https://doi.org/10.1016/j.ejmp.2024.103407y Fulltext
856u https://uu.diva-portal.org/smash/get/diva2:1878520/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-533631
8564 8u https://doi.org/10.1016/j.ejmp.2024.103407

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy