SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-70671"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-70671" > Analysis of microso...

  • Lavén, MartinUppsala universitet,Kemiska institutionen,Analytisk kemi (författare)

Analysis of microsomal metabolic stability using high-flow-rate extraction coupled to capillary liquid chromatography-mass spectrometry

  • Artikel/kapitelEngelska2004

Förlag, utgivningsår, omfång ...

  • 2004
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-70671
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-70671URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • A method described for on-line high-speed extraction of microsomal samples and analysis by capillary liquid chromatography - mass spectrometry (LC-MS) for the determination of metabolic stability in connection with the development of positron emission tomography (PET) tracers. the method allowed direct injections of large sample volumes at a fast extraction rate, providing a gain in both sensitivity and sample preparation time. The calibration curve of the test compound flumazenil (Ro 15-1788) was linear in the concentration range of 1-150 nM, with a correlation coefficient exceeding 0.999. The accuracy of the method ranged from 98 to 101%. A high precision was obtained, with mean intra-assay and inter-assay relative standard deviations of at most 1.4 and 1.5%, respectively, for quality control (QC) samples. The extraction efficiency was determined to be 99.4%, the total recovery 96% and the carryover to <0.23%. Extractions were performed in a concentration interval of 30-300 nM without any sign of column overload. The method was successfully used for determining the microsomal metabolic stability of flumazenil. As a result, the described analysis system is currently used for metabolic screening of PET tracer candidates in our laboratory.

Ämnesord och genrebeteckningar

  • High-flow-rate extraction
  • Metabolic stability
  • Positron emission tomography

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Markides, Karin E.Uppsala universitet,Kemiska institutionen,Analytisk kemi (författare)
  • Långström, Bengt (författare)
  • Uppsala universitetKemiska institutionen (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Chromatography B:806, s. 119-126

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lavén, Martin
Markides, Karin ...
Långström, Bengt
Artiklar i publikationen
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy