SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-73881"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-73881" > Imaging of peptide ...

Imaging of peptide adsorption to microfluidic channels in a plastic compact disc using a positron emitting radionuclide

Lavén, Martin (författare)
Uppsala universitet,Kemiska institutionen,Analytisk kemi
Velikyan, Irina (författare)
Djodjic, Majda (författare)
visa fler...
Ljung, Jenny (författare)
Berglund, Oskar (författare)
Markides, Karin (författare)
Uppsala universitet,Kemiska institutionen,Analytisk kemi
Långström, Bengt (författare)
Wallenborg, Susanne (författare)
visa färre...
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Lab Chip. ; :5, s. 756-763
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A method for studying peptide-surface interactions within microfluidic channels by radionuclide imaging is described. With the high surface area-to-volume ratio of channels in miniaturised devices, combined with low amunts of analyte, non-specific peptide adsorption is a critical issue. The objective of the study was therefore to develop a method capable of direct detection of adsorbed peptide within microfluidic channels. A micro-device consisting of channels moulded in a plastic compact disc was chosen for the study, together with two selected peptides of different lengths and isolelectric point (pI) values. A bifunctional chelator, DOTA, was attached to the peptide by conjugation and labelled with the short-lived positron emitting radionuclide 68Ga. Quantitative images of radiotracer distribution within the microfluidic channels were obtained using a PhosphorImager system. The power of the method was demonstrated by the ability to clearly measure changes in adsorption when varying a number of parameters that typically affect peptide adsorption. These included surface modifications, analyte concentration, pH, and ionic strength. Additionally, two quantification methods were developed and compared. Radionuclide imaging also permitted visualisation of adsorption and release processes in microchannel chromatographic columns. The results suggest that radionuclide imaging is a suitable tool not only for the study of peptide adsorption to the microchannels presented in this study but also as a versatile tool to measure peptide-surface interactions in a wide variety of miniaturised structures and devices.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy