SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-95904"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-95904" > Sentinel node biops...

Sentinel node biopsy for breast cancer larger than 3 cm in diameter

Schüle, Jana (författare)
Uppsala universitet,Centrum för klinisk forskning, Västerås
Frisell, Jan (författare)
Karolinska Institutet
Ingvar, Christian (författare)
Lund University,Lunds universitet,Kirurgi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Surgery (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Bergkvist, Leif (författare)
Uppsala universitet,Centrum för klinisk forskning, Västerås
visa färre...
 (creator_code:org_t)
2007-04-16
2007
Engelska.
Ingår i: British Journal of Surgery. - : Oxford University Press (OUP). - 0007-1323 .- 1365-2168. ; 94:8, s. 948-951
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background:Sentinel node biopsy (SNB) is a standard staging procedure in early breast cancer. Its suitability for larger tumours has been questioned. This study evaluated the reliability of SNB in women with invasive breast cancer larger than 3 cm in diameter who were clinically axillary node negative.Methods:Some 109 women with a tumour larger than 3 cm on pathological analysis were identified from the Swedish prospective SNB database. They were included if a completion axillary clearance was planned, regardless of SNB results.Results:The sentinel node detection rate was 103 (94·5 per cent) of 109. The overall false-negative rate was eight (13 per cent) of 64. Although a preoperative diagnosis of multifocal tumour was an exclusion criterion, 16 such cases were revealed on postoperative pathological examination. The false-negative rate in this subgroup was higher than that in women with a unifocal tumour (four (31 per cent) of 13 versus four (8 per cent) of 51; P = 0·012). No other significant predictors of a false-negative sentinel node biopsy were identified.Conclusion:SNB is feasible in patients with unifocal breast tumours larger than 3 cm. When large tumour size coincides with multifocality, however, the false-negative rate seems to be increased and a completion axillary clearance should be considered even if the SNB is negative.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Mammary gland diseases
Breast cancer
Treatment
Surgery
Medicine
Diameter
Mammary gland
Anatomic pathology
Biopsy
Sentinel lymph node
Malignant tumor
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy