Sökning: onr:"swepub:oai:gup.ub.gu.se/100191" >
Intensity-modulated...
Intensity-modulated radiotherapy of nasopharyngeal carcinoma: a comparative treatment planning study of photons and protons.
-
- Taheri-Kadkhoda, Zahra, 1969 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
-
- Björk-Eriksson, Thomas, 1960 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
-
Nill, Simeon (författare)
-
visa fler...
-
Wilkens, Jan J (författare)
-
Oelfke, Uwe (författare)
-
- Johansson, Karl-Axel (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
-
Huber, Peter E (författare)
-
Münter, Marc W (författare)
-
visa färre...
-
(creator_code:org_t)
- 2008
- 2008
- Engelska.
-
Ingår i: Radiation oncology (London, England). - 1748-717X. ; 3
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- BACKGROUND: The aim of this treatment planning study was to investigate the potential advantages of intensity-modulated (IM) proton therapy (IMPT) compared with IM photon therapy (IMRT) in nasopharyngeal carcinoma (NPC). METHODS: Eight NPC patients were chosen. The dose prescriptions in cobalt Gray equivalent (GyE) for gross tumor volumes of the primary tumor (GTV-T), planning target volumes of GTV-T and metastatic (PTV-TN) and elective (PTV-N) lymph node stations were 72.6 GyE, 66 GyE, and 52.8 GyE, respectively. For each patient, nine coplanar fields IMRT with step-and-shoot technique and 3D spot-scanned three coplanar fields IMPT plans were prepared. Both modalities were planned in 33 fractions to be delivered with a simultaneous integrated boost technique. All plans were prepared and optimized by using the research version of the inverse treatment planning system KonRad (DKFZ, Heidelberg). RESULTS: Both treatment techniques were equal in terms of averaged mean dose to target volumes. IMPT plans significantly improved the tumor coverage and conformation (P < 0.05) and they reduced the averaged mean dose to several organs at risk (OARs) by a factor of 2-3. The low-to-medium dose volumes (0.33-13.2 GyE) were more than doubled by IMRT plans. CONCLUSION: In radiotherapy of NPC patients, three-field IMPT has greater potential than nine-field IMRT with respect to tumor coverage and reduction of the integral dose to OARs and non-specific normal tissues. The practicality of IMPT in NPC deserves further exploration when this technique becomes available on wider clinical scale.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Nyckelord
- Algorithms
- Computer Simulation
- Humans
- Nasopharyngeal Neoplasms
- radiotherapy
- Photons
- therapeutic use
- Protons
- therapeutic use
- Radiotherapy Dosage
- Radiotherapy Planning
- Computer-Assisted
- Radiotherapy
- Intensity-Modulated
- adverse effects
- methods
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas