Evaluation of subjective assessment of the low-contrast visibility in constancy control of computed tomography

Thilander-Klang, Anne, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Ledenius, Kerstin, 1979 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Hansson, Jonny (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa fler...
Sund, Patrik (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa färre...
 (creator_code:org_t)
2010-02-22
2010
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 449-454
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of the present work was to investigate the reliability of subjective assessments of the low-contrast visibility in constancy control of computed tomography (CT). Axial CT images of a low-contrast phantom were acquired on an 8-slice multi-detector CT scanner at nine tube current settings ranging from 75 to 440 mA. Five medical physicists assessed the visibility of the low-contrast details in two sessions. In the first session, containing 54 images, the visibility was rated on an absolute scale by determining the number of visible details in each contrast group in each image. In the second session, 180 image pairs were presented to the observers with the task of determining if the two images had been acquired under identical conditions or not. In the absolute session, both the intra- and inter-observer variabilities were high. In the relative session, the variability was smaller, but an exposure difference of 50 % was needed for all observers to correctly identify a change in all cases. In conclusion, the present study indicates that subjective assessments of the low-contrast visibility in constancy control of CT are not reliable.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy