Bisphosphonate coating might improve fixation of dental implants in the maxilla: A pilot study
-
- Abtahi, Jahan (författare)
- Linköpings universitet,Ortopedi och idrottsmedicin,Hälsouniversitetet
-
- Tengvall, Pentti (författare)
- Linköpings universitet,Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials,Tillämpad Fysik,Tekniska högskolan,Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, Gothenburg, Sweden
-
- Aspenberg, Per (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Ortopedi och idrottsmedicin,Hälsouniversitetet,Ortopedkliniken Linköping
-
(creator_code:org_t)
- Elsevier Science B.V., Amsterdam, 2010
- 2010
- Engelska.
-
Ingår i: International Journal of Oral and Maxillofacial Surgery. - : Elsevier Science B.V., Amsterdam. - 0901-5027 .- 1399-0020. ; 39:7, s. 673-677
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- This pilot study evaluates the clinical stability of bisphosphonate-coated dental implants placed using a two-stage surgical procedure in five patients. Each patient received seven regular Brånemark implants, one of which was coated with bisphosphonate in a fibrinogen matrix. The coated implant was inserted where the bone was expected to have the least favourable quality. The level of the marginal bone around each implant was measured by intraoral periapical radiographs and implant stability was recorded using resonance frequency measurements. Frequency values (ISQ) were obtained peroperatively before flap closure and after 6 months at abutment connection. At abutment connection the bisphosphonate-coated implants were removed en bloc in two patients for histological examination. An animal experiment had previously confirmed that gamma-sterilization did not reduce bioactivity of the bisphosphonate coating. In each patient, the bisphosphonate-coated implant showed the largest improvement in ISQ level of all implants. Their values at the start tended to be lower, and the absolute value at 6 months did not differ. No complications occurred with the coated implants. Histology showed no abnormalities. Improvement in ISQ values was an expected effect of the bisphosphonate coating, but could be due to the choice of insertion site. This finding warrants a randomized, blinded study.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Industriell bioteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Industrial Biotechnology (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Annan klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Other Clinical Medicine (hsv//eng)
Nyckelord
- bisphosphonate coating; dental implants; fixation
- bisphosphonate coating; dental implants; fixation
- MEDICINE
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas