Sökning: onr:"swepub:oai:gup.ub.gu.se/164387" >
Pulmonary nodule si...
Pulmonary nodule size evaluation with chest tomosynthesis.
-
- Johnsson, Åse (Allansdotter), 1966 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Fagman, Erika (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Vikgren, Jenny, 1957 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
visa fler...
-
- Fisichella, Valeria A, 1974 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Boijsen, Marianne, 1948 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Flinck, Agneta, 1953 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Kheddache, Susanne, 1949 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Svalkvist, Angelica (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
- Båth, Magnus, 1974 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
visa färre...
-
(creator_code:org_t)
- Radiological Society of North America (RSNA), 2012
- 2012
- Engelska.
-
Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 1527-1315 .- 0033-8419. ; 265:1, s. 273-82
- Relaterad länk:
-
https://pubs.rsna.or...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: To evaluate intra- and interobserver variability, as well as agreement for nodule size measurements on chest tomosynthesis and computed tomographic (CT) images. Materials and Methods: The Regional Ethical Review Board approved this study, and all participants gave written informed consent. Thirty-six segmented nodules in 20 patients were included in the study. Eight observers measured the left-to-right, inferior-to-superior, and longest nodule diameters on chest tomosynthesis and CT images. Intra- and interobserver repeatability, as well as agreement between measurements on chest tomosynthesis and CT images, were assessed as recommended by Bland and Altman. Results: The difference between the mean manual and the segmented diameter was -2.2 and -2.3 mm for left-to-right and -2.6 and -2.2 mm for the inferior-to-superior diameter for measurements on chest tomosynthesis and CT images, respectively. Intraobserver 95% limits of agreement (LOA) for the longest diameter ranged from a lower limit of -1.1 mm and an upper limit of 1.0 mm to -1.8 and 1.8 mm for chest tomosynthesis and from -0.6 and 0.9 mm to -3.1 and 2.2 mm for axial CT. Interobserver 95% LOA ranged from -1.3 and 1.5 mm to -2.0 and 2.1 mm for chest tomosynthesis and from -1.8 and 1.1 mm to -2.2 and 3.1 mm for axial CT. The 95% LOA concerning the mean of the observers' measurements of the longest diameter at chest tomosynthesis and axial CT were ±2.1 mm (mean measurement error, 0 mm). For the different observers, the 95% LOA between the modalities ranged from -2.2 and 1.6 mm to -3.2 and 2.8 mm. Conclusion: Measurements on chest tomosynthesis and CT images are comparable, because there is no evident bias between the modalities and the repeatability is similar. The LOA between measurements for the two modalities raise concern if measurements from chest tomosynthesis and CT were to be used interchangeably. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12111459/-/DC1.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Johnsson, Åse (A ...
-
Fagman, Erika
-
Vikgren, Jenny, ...
-
Fisichella, Vale ...
-
Boijsen, Mariann ...
-
Flinck, Agneta, ...
-
visa fler...
-
Kheddache, Susan ...
-
Svalkvist, Angel ...
-
Båth, Magnus, 19 ...
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Radiology
- Av lärosätet
-
Göteborgs universitet