Sökning: onr:"swepub:oai:gup.ub.gu.se/178842" >
Dual Conjugate Adap...
Dual Conjugate Adaptive Optics Prototype for Wide Field High Resolution Retinal Imaging
-
- Popovic, Zoran, 1966 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
-
- Thaung, Jörgen, 1965 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
-
Knutsson, Per, 1978 (författare)
-
visa fler...
-
Owner-Petersen, Mette, 1942 (författare)
-
visa färre...
-
(creator_code:org_t)
- 2012-12-18
- 2012
- Engelska.
-
Ingår i: Adaptive Optics Progress. - Rijeka : Intech. - 9789535108948 ; , s. 3-21
- Relaterad länk:
-
https://mts.intechop...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.5...
-
visa färre...
Abstract
Ämnesord
Stäng
- Retinal imaging is limited due to optical aberrations caused by imperfections in the optical media of the eye. Consequently, diffraction limited retinal imaging can be achieved if optical aberrations in the eye are measured and corrected. Information about retinal pathology and structure on a cellular level is thus not available in a clinical setting but only from histological studies of excised retinal tissue. In addition to limitations such as tissue shrinkage and distortion, the main limitation of histological preparations is that longitudinal studies of disease progression and/or results of medical treatment are not possible. Adaptive optics (AO) is the science, technology and art of capturing diffraction-limited images in adverse circumstances that would normally lead to strongly degraded image quality and loss of resolution. In non-military applications, it was first proposed and implemented in astronomy. AO technology has since been applied in many disciplines, including vision science, where retinal features down to a few microns can be resolved by correcting the aberrations of ocular optics. As the focus of this chapter is on AO retinal imaging, we will focus our description to this particular field.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
Nyckelord
- adaptive optics
- retina
- cone
- capillary
- FAZ
- cell density
- cell separation
Publikations- och innehållstyp
- vet (ämneskategori)
- kap (ämneskategori)
Hitta via bibliotek
Till lärosätets databas