Mean Expected Error in Prediction of Total Body Water: A True Accuracy Comparison between Bioimpedance Spectroscopy and Single Frequency Regression Equations
-
- Seoane, Fernando (författare)
- Högskolan i Borås,KTH,Medicinska sensorer, signaler och system,Univ Boras, Fac Care Sci Work Life & Social Welfare, Sweden,Akademin för vård, arbetsliv och välfärd,KTH-School of Technology and Health
-
- Abtahi, S. (författare)
- Karolinska Institutet
-
- Abtahi, Farhad, 1981- (författare)
- Karolinska Institutet,KTH,Medicinska sensorer, signaler och system,Karolinska Inst, Dept Clin Sci Intervent & Technol, Sweden,KTH-School of Technology and Health
-
visa fler...
-
- Ellegård, Lars, 1958 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,University of Gothenburg
-
- Johannsson, Gudmundur, 1960 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,University of Gothenburg
-
- Bosaeus, Ingvar, 1950 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,University of Gothenburg
-
- Ward, L. C. (författare)
- University of Queensland
-
visa färre...
-
(creator_code:org_t)
- Hindawi Limited, 2015
- 2015
- Engelska.
-
Ingår i: Biomed Research International. - : Hindawi Limited. - 2314-6133 .- 2314-6141. ; 2015:Article ID 656323
- Relaterad länk:
-
http://downloads.hin...
-
visa fler...
-
https://doi.org/10.1...
-
http://dx.doi.org/10...
-
https://kth.diva-por... (primary) (Raw object)
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun's prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Annan medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Other Medical Engineering (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Urology and Nephrology (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
Nyckelord
- BIOELECTRICAL-IMPEDANCE ANALYSIS
- FAT-FREE MASS
- FLUID VOLUME
- HEMODIALYSIS-PATIENTS
- DILUTION METHODS
- WHOLE-BODY
- VALIDATION
- MODEL
- Biotechnology & Applied Microbiology
- Medicine
- Research & Experimental
- URENBERG P
- 1995
- BRITISH JOURNAL OF NUTRITION
- V73
- P349
- Bioimpedance Spectroscopy
- Människan i vården
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Seoane, Fernando
-
Abtahi, S.
-
Abtahi, Farhad, ...
-
Ellegård, Lars, ...
-
Johannsson, Gudm ...
-
Bosaeus, Ingvar, ...
-
visa fler...
-
Ward, L. C.
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Medicinsk biotek ...
-
och Biomedicinsk lab ...
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Elektroteknik oc ...
-
och Signalbehandling
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
-
och Annan medicintek ...
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Urologi och njur ...
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
-
och Medicinsk labora ...
- Artiklar i publikationen
-
Biomed Research ...
- Av lärosätet
-
Göteborgs universitet
-
Kungliga Tekniska Högskolan
-
Högskolan i Borås
-
Karolinska Institutet