Sökning: onr:"swepub:oai:gup.ub.gu.se/232804" >
Early Osseointegrat...
Early Osseointegration Events on Neoss® ProActive and Bimodal Implants: A Comparison of Different Surfaces in an Animal Model
-
Grossi-Oliveira, G.A. (författare)
-
Antunes, A.A. (författare)
-
Elias, C.N. (författare)
-
visa fler...
-
- Wennerberg, Ann (författare)
- Malmö högskola,Odontologiska fakulteten (OD)
-
- Sennerby, Lars, 1960 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 1,Institute of Odontology, Section 1
-
Salata, L.A. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2014-02-20
- 2015
- Engelska.
-
Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley. - 1523-0899 .- 1708-8208. ; 17:6, s. 1060-1072
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- © 2015 Wiley Periodicals, Inc. Background: Cell interactions, adherence, and osseointegration at the bone-implant interface can be directly influenced by the surface properties of the titanium implant. Purpose: To characterize osseointegration of Neoss® implants with conventional (control group) and hydrophilic (test group) surface treatments. Materials and Methods: Six Labrador dogs received Neoss implants with conventional and hydrophilic surfaces. The bone-implant interfaces were evaluated 1 and 4 weeks after implantation, and osseointegration was evaluated using histological, histomorphometric, fluorescence, and resonance frequency analyses. The surfaces were also subjected to topographic and hydrophilicity analyses. Results: The topographic analyses revealed increased surface roughness in the test group compared with the control group (surface area roughness 0.42 and 0.78μm, respectively, for control and test group surfaces; p≤.05). The wettability values were higher in the test group (contact angles 67.2° and 27.2° for the control and test group surfaces, respectively; p≤.05). Implants in the test group also exhibited better stability, more bone-implant contact, and increased bone area compared with implants in the control group. Conclusion: Neoss implants in the test group improved bone formation in the early stages of osseointegration compared with implants in the control group.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Nyckelord
- Animal model
- Bone-implant interface
- Implant surface
- Surface properties
- Surface topography
- animal model
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas