Sökning: onr:"swepub:oai:gup.ub.gu.se/248250" >
Slightly superior p...
Slightly superior performance of bioimpedance spectroscopy over single frequency regression equations for assessment of total body water.
-
- Seoane, Fernando (författare)
- Högskolan i Borås,KTH,Medicinska sensorer, signaler och system,University of Boras, Sweden,Akademin för vård, arbetsliv och välfärd,KTH-School of Technology and Health
-
- Abtahi, S (författare)
- Karolinska Institutet
-
- Abtahi, Farhad, 1981- (författare)
- Karolinska Institutet,KTH,Medicinska sensorer, signaler och system,Karolinska Institute, Sweden,KTH-School of Technology and Health
-
visa fler...
-
- Ellegård, Lars, 1958 (författare)
- Sahlgrenska University Hospital
-
- Johannsson, Gudmundur, 1960 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,Sahlgrenska University Hospital
-
- Bosaeus, Ingvar, 1950 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,University of Gothenburg
-
- Ward, L C (författare)
- University of Queensland
-
visa färre...
-
(creator_code:org_t)
- IEEE, 2015
- 2015
- Engelska.
-
Ingår i: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE. 25-29 Aug. 2015, Milan, Italy.. - : IEEE. - 1094-687X .- 1558-4615. - 9781424492718 - 9781424492701 ; 2015, s. 3707-10
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Electrical bioimpedance has been used for several decades to assess body fluid distribution and body composition by using single frequency and bioimpedance spectroscopic (BIS) techniques. It remains uncertain whether BIS methods have better performance compare to single frequency regression equations. In this work the performance of two BIS methods and four different 50 kHz single frequency prediction equations was studied in a data set of wrist-to-ankle tetrapolar BIS measurements (5-1000 kHz) together with reference values of total body water obtained by tritium dilution in 92 patients. Data were compared using regression techniques and Bland-Altman plots. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Limits of agreement analysis indicated that the population level performance of Sun's prediction equations was very similar to the performance of both BIS methods. However, BIS methods in practice have slightly better predictive performance than the single-frequency equations as judged by higher correlation and the limits of agreement from the Bland-Altman analysis. In any case, the authors believe that an accurate evaluation of performance of the methods cannot be done as long as the evaluation is done using Bland-Altman analysis, the commonly accepted technique for this kind of performance comparisons.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Annan medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Other Medical Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
Nyckelord
- Aged
- Ankle
- physiology
- Artifacts
- Body Water
- Dielectric Spectroscopy
- methods
- Female
- Humans
- Male
- Middle Aged
- Regression Analysis
- Tritium
- Wrist
- physiology
- Atmospheric measurements
- Människan i vården
Publikations- och innehållstyp
- ref (ämneskategori)
- kon (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Seoane, Fernando
-
Abtahi, S
-
Abtahi, Farhad, ...
-
Ellegård, Lars, ...
-
Johannsson, Gudm ...
-
Bosaeus, Ingvar, ...
-
visa fler...
-
Ward, L C
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Endokrinologi oc ...
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
-
och Annan medicintek ...
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Elektroteknik oc ...
-
och Signalbehandling
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
- Artiklar i publikationen
-
Engineering in M ...
-
Annual Internati ...
- Av lärosätet
-
Göteborgs universitet
-
Kungliga Tekniska Högskolan
-
Högskolan i Borås
-
Karolinska Institutet