SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/249631"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/249631" > High resolution dig...

High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors

Vilhelmsson Timmermand, Oskar (författare)
Lund University,Lunds universitet,Tumörmikromiljö,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Tumor microenvironment,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
Nilsson, Jenny (författare)
University of Gothenburg,Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Sahlgrenska Academy
Strand, Sven Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Tumörmikromiljö,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Tumor microenvironment,Section I,Department of Clinical Sciences, Lund
visa fler...
Elgqvist, Jörgen, 1963 (författare)
University of Gothenburg,Gothenburg University,Göteborgs universitet,Institutionen för fysik (GU),Department of Physics (GU)
visa färre...
 (creator_code:org_t)
2016-11-23
2016
Engelska.
Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 43:12, s. 6632-6643
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Three dosimetry models based on either dose point kernels or Monte Carlo simulations were used and evaluated. The second and overlapping aim, was to perform DAR imaging and dosimetric analysis of the distribution of radioactivity, and hence the absorbed dose rate, in tumor sections at an early time point after injection during radioimmunotherapy using 177Lu-h11B6, directed against the human kallikrein 2 antigen.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Nyckelord

177 Lu
90 Y
alpha-particles
digital autoradiography
dosimetry
prostate cancer
Lu
Y

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Vilhelmsson Timm ...
Nilsson, Jenny
Strand, Sven Eri ...
Elgqvist, Jörgen ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Cancer och onkol ...
NATURVETENSKAP
NATURVETENSKAP
och Fysik
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Annan fysik
Artiklar i publikationen
Medical Physics
Av lärosätet
Göteborgs universitet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy