SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/257582"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/257582" > Accuracy of Proxima...

Accuracy of Proximal Caries Depth Measurements: Comparison of Two Computed Cone Beam Tomography and Storage Phosphor Plate Systems

Sener, E. (författare)
Baksi, B. G. (författare)
Horasan, S. (författare)
visa fler...
Gröndahl, Hans-Göran, 1940 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Kose, T. (författare)
visa färre...
 (creator_code:org_t)
2017-08-01
2017
Engelska.
Ingår i: Meandros Medical and Dental Journal. - : Galenos Yayinevi. - 2149-9063. ; 18:2, s. 108-114
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: The aim of this study was to compare the accuracy of NewTom 9000 [cone beam computerized tomography (CBCT)], Accu-I-Tomo [limited CBTC (LCBCT)] and Digora Optime [storage phosphor plate (SPP)] imaging systems in assessing the depths of defects with different shapes and sizes on the proximal surfaces of teeth. Materials and Methods: Thirty out of 50 incisive teeth with sound proximal surfaces were divided into three equal groups. Mechanical defects of different sizes and depths were created on their proximal surfaces and teeth were placed in acrylic blocks with approximal contacts. Radiographs of the blocks were obtained with CBCT, LCBCT and SPP systems. The depth measurements of 60 artificial defects were performed by 3 radiologists in the digital radiographs. The gold standard (true measure) was defined as the mean of the 2 observers' measurements on the microscopic sections. Results from imaging systems and true depths were compared using Bland-Altman plots. The agreement was determined with intra-class correlation coefficient. Results: Maximum deviation from the true length in axial and sagittal slices of CBCT system was 2 mm [95% confidence interval (CI) 2.60-0.60] and 1.5 mm (95% CI 0.30-2.30) respectively while the deviation of LCBCT was 0.66 mm (95% CI 0.53-2.22) and 0.37 mm (95% CI 0.50-2.25). The deviation from truth for SPP was 0.66 mm (95% CI 0.33-2.25). Correlation among observers was 0.487 and 0.700 respectively, for CBCT axial and sagittal slices; while it was 0.979 and 0.985 for LCBCT and 0.979 for SPP. Conclusion: Images obtained with the Accu-I-Tomo LCBCT system were more accurate than Newtom CBCT and Digora SPP system for measurement of caries lesion depth. Correlation among observers was higher for LCBCT and SPP systems compared with CBCT system.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Approximal caries
depth measurement
cone beam computerized tomography
diagnostic-accuracy
approximal caries
digital radiography
film
radiography
modalities
lesions
images
resolution
exposure

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sener, E.
Baksi, B. G.
Horasan, S.
Gröndahl, Hans-G ...
Kose, T.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Meandros Medical ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy