SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/276275"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/276275" > Projection-based re...

Projection-based respiratory-resolved left ventricular volume measurements in patients using free-breathing double golden-angle 3D radial acquisition.

Holst, Karen (författare)
Fyrdahl, Alexander (författare)
Karolinska Institutet
Caidahl, Kenneth, 1949 (författare)
Karolinska Institutet,Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
visa fler...
Ugander, Martin (författare)
Karolinska Institutet
Sigfridsson, Andreas (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2018-12-12
2019
Engelska.
Ingår i: Magma. - : Springer Science and Business Media LLC. - 1352-8661. ; 32:3, s. 331-341
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To refine a new technique to measure respiratory-resolved left ventricular end-diastolic volume (LVEDV) in mid-inspiration and mid-expiration using a respiratory self-gating technique and demonstrate clinical feasibility in patients.Ten consecutive patients were imaged at 1.5T during 10min of free breathing using a 3D golden-angle radial trajectory. Two respiratory self-gating signals were extracted and compared: from the k-space center of all acquired spokes, and from a superior-inferior projection spoke repeated every 64ms. Data were binned into end-diastole and two respiratory phases of 15% respiratory cycle duration in mid-inspiration and mid-expiration. LVED volume and septal-lateral diameter were measured from manual segmentation of the endocardial border.Respiratory-induced variation in LVED size expressed as mid-inspiration relative to mid-expiration was, for volume, 1±8% with k-space-based self-gating and 8±2% with projection-based self-gating (P=0.04), and for septal-lateral diameter, 2±2% with k-space-based self-gating and 10±1% with projection-based self-gating (P=0.002).Measuring respiratory variation in LVED size was possible in clinical patients with projection-based respiratory self-gating, and the measured respiratory variation was consistent with previous studies on healthy volunteers. Projection-based self-gating detected a higher variation in LVED volume and diameter during respiration, compared to k-space-based self-gating.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Cardiac imaging; Golden-angle; Radial; Respiratory resolved; Self-gating; Three-dimensional

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Magma (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy