SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/290448"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/290448" > Immediate vs early ...

Immediate vs early loading of 6.6 mm flapless-placed single implants: 9 years after-loading report of a split-mouth randomised controlled trial.

Cannizzaro, Gioacchino (författare)
Felice, Pietro (författare)
Trullenque-Eriksson, Anna (författare)
visa fler...
Lazzarini, Matteo (författare)
Velasco-Ortega, Eugenio (författare)
Esposito, Marco, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
2018
2018
Engelska.
Ingår i: European journal of oral implantology. - 1756-2406. ; 11:2, s. 163-173
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To evaluate the long-term effectiveness of 6.6 mm long flapless-placed single implants loaded immediately or early loaded at 6 weeks.Thirty patients each received two single Nanotite External Hex Biomet 3i implants, which were then randomly allocated to be either immediately or early loaded, according to a split-mouth design. Implants had to be inserted with a torque superior to 40 Ncm. Provisional crowns were put in slight occlusal contact and replaced by definitive crowns 3 months after loading. Patients were followed for 9 years after loading. Outcome measures were implant failures, biological and biomechanical complications, peri-implant marginal bone level changes and patient preference.A total of 29 implants were immediately loaded, while 31 were early loaded. Nine years after loading, three patients dropped out. One implant failed in each group within 2 months after loading. One patient asked for the immediately loaded crown to be remade for aesthetic reasons and then again to have both metal-ceramic crowns replaced by full ceramic crowns. Another patient had his immediately loaded crown remade after repeated debonding. Six patients from each group experienced complications, the difference being not statistically significant (difference of proportions = 0.00; 95% CI -0.20 to 0.20, P = 1.000). Peri-implant bone loss was 0.60 mm for patients with immediately loaded implants and 0.46 mm for early loaded ones, which was not significantly different (mean difference = 0.14 mm, 95% CI -0.13 to 0.41, P = 0.283). All but one patient had no preference for either procedure after 9 years.Flapless-placed 6.6 mm long single implants can be immediately loaded and remain successful up to 9 years after loading. Conflict-of-interest statement:

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Nyckelord

Dental Implantation
Endosseous
Dental Implants
Single-Tooth
Dental Prosthesis Design
Female
Humans
Immediate Dental Implant Loading
Male
Time Factors

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy