SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/300139"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/300139" > Novel method to det...

Novel method to determine recursive filtration and noise reduction in fluoroscopic imaging - a comparison of four different vendors.

Konst, Bente (författare)
Nøtthellen, Jacob (författare)
Nalum Naess, Stine (författare)
visa fler...
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
visa färre...
 (creator_code:org_t)
2020-12-14
2021
Engelska.
Ingår i: Journal of applied clinical medical physics. - : Wiley. - 1526-9914. ; 22:1, s. 281-292
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study attempted to develop a method to measure the applied recursive filtration and to determine the noise reduction of four different fluoroscopic systems. The study also attempted to elucidate the importance of considering the recursive filter for quality control tests concerning signal-to-noise ratio (SNR) or image quality. The vendor's settings for recursive filtration factor (β) are, unfortunately, often not available. Hence, a method to determine the recursive filtration and associated noise reduction would be useful.The recursive filter was determined by using a single fluoroscopic series and the method presented in this study. The theoretical noise reduction based on the choice of β was presented. In addition, the corresponding noise reduction, evaluated as the ratio of the standard deviation of the pixel value between a series with β equal to zero (recursive filtration off) and β>0, was determined for different pulse rates given by pulses per second (pps), doses (mAs) and recursive filter. The images were acquired using clinically relevant radiation quality and quantity.The presented method to measure the recursive filter exhibited high accuracy (1.08%) and precision (1.48%). The recursive filtration and noise reduction were measured for several settings for each vendor. The recursive filtration settings and associated recursive filtration factors for four different vendors were presented.This study presented an accurate method to determine applied recursive filtration, which was easy to determine. Hence, for all quality control purposes, including noise evaluation, it was possible to consider the essential noise reduction given by the settings for recursive filtration. It was also possible to compare the recursive filtration settings and associated recursive filtration within and between vendors.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)