SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/313506"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/313506" > IDACstar2.0: A MCNP...

IDACstar2.0: A MCNP application to perform realistic dose estimations from internal or external contamination with radiopharmaceuticals

Andersson, Martin (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Sahlgrenska Centrum för Cancerforskning (SCCR),Institute of Clinical Sciences, Department of Medical Radiation Sciences,Sahlgrenska Center for Cancer Research (SCCR),Sahlgrenska Academy
Almén, A. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Medical Radiation Physics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
Ören, Ü (författare)
Barsebäck Kraft AB
 (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: Radiation Physics and Chemistry. - : Elsevier BV. - 0969-806X. ; 193
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The IDACstar (Internal Dose Assessment by Computer) software is a Monte Carlo based standalone MCNP input generator software developed to perform complex radiation dose calculations using both the paediatric and adult ICRP reference phantoms. An extension of the IDACstar software was applied to two different exposure scenarios. One of the scenarios was a hypothetical case of a contaminated diaper from urine of a 1-year old patient undergoing a diagnostic kidney examination with 99mTc-labelled mercaptoacetyl triglycerine (MAG3), which resulted in an effective dose estimate of 0.088 mSv to the child. The second case was a clinical case of 18F-FDG extravasation in an adult patient and applied to all 10 age-specific phantoms with weight-modified administrations of the radiopharmaceutical. The effective dose was estimated for the 15-, 10-, 5- and 1- year old as 5.1 mSv, 4.9 mSv, 4.7 mSv, and 4.7 mSv, respectively. The updated version of the IDACstar software provides the possibility of performing realistic dose estimations to paediatric patients from internal or external contamination with radiopharmaceuticals. © 2021

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Dose equivalent/effective dose etc
Monte Carlo
Radioactive contamination
Radiopharmaceuticals
Contamination
Diagnosis
Pediatrics
Phantoms
Dose assessments
Dose equivalent
Dose estimations
Effective dose
External contamination
Internal contaminations
Radiopharmaceutical
Monte Carlo methods

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Andersson, Marti ...
Almén, A.
Ören, Ü
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Cancer och onkol ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation Physic ...
Av lärosätet
Göteborgs universitet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy