Experimental validation of a mean systemic pressure analog against zero-flow measurements in porcine VA-ECMO

Möller, Per Werner (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
Heinisch, P. P. (författare)
Hana, A. (författare)
visa fler...
Bachmann, K. F. (författare)
Sondergaard, S. (författare)
Jakob, S. M. (författare)
Takala, J. (författare)
Berger, D. (författare)
visa färre...
 (creator_code:org_t)
American Physiological Society, 2022
2022
Engelska.
Ingår i: Journal of Applied Physiology. - : American Physiological Society. - 8750-7587 .- 1522-1601. ; 132:3, s. 726-736
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The mean systemic pressure analog (Pmsa), calculated from running hemodynamic data, estimates mean systemic filling pressure (MSFP). This post hoc study used data from a porcine veno-arterial extracorporeal membrane oxygenation (ECMO) model [n = 9; Sus scrofa domesticus; ES breed (Schweizer Edelschwein)] with eight experimental conditions; Euvolemia [a volume state where ECMO flow produced normal mixed venous saturation (SVO2) without vascular collapse]; three levels of increasing norepinephrine infusion (Vasoconstriction 1-3); status after stopping norepinephrine (Post Vasoconstriction); and three steps of volume expansion (10 mL/kg crystalloid bolus) (Volume Expansion 1-3). In each condition, Pmsa and a "reduced-pumpspeed-Pmsa" (Pmsared) were calculated from baseline and briefly reduced pump speeds, respectively. We calculated agreement for absolute values (per condition) and changes (between consecutive conditions) of Pmsa and Pmsared, against MSFP at zero ECMO flow. Euvolemia venous return driving pressure was 5.1 +/- 2.0 mmHg. Bland-Altman analysis for Pmsa vs. MSFP (all conditions; 72 data pairs) showed bias (confidence interval) 0.5 (0.1-0.9) mmHg; limits of agreement (LoA) -2.7 to 3.8 mmHg. Bias for DPmsa vs. DMSFP (63 data pairs): 0.2 (-0.2 to 0.6) mmHg, LoA -3.2 to 3.6 mmHg. Bias for Pmsared vs. MSFP (72 data pairs): 0.0 (-0.3 to -0.3) mmHg; LoA -2.3 to 2.4 mmHg. Bias for DPmsared vs. DMSFP (63 data pairs) was 0.2 (-0.1 to 0.4) mmHg; LoA -1.8 to 2.1 mmHg. In conclusion, during veno-arterial ECMO, under clinically relevant levels of vasoconstriction and volume expansion, Pmsa accurately estimated absolute and changing values of MSFP, with low between-method precision. The within-method precision of Pmsa was excellent, with a least significant change of 0.15 mmHg. NEW & NOTEWORTHY This is the first study ever to validate the mean systemic pressure analog (Pmsa) against the reference mean systemic filling pressure (MSFP) determined at full arterio-venous pressure equilibrium. Using a porcine ECMO model with clinically relevant levels of vasoconstriction and volume expansion, we showed that Pmsa accurately estimated absolute and changing values of MSFP, with a poor between-method precision. The within-method precision of Pmsa was excellent.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

cardiac output
ECMO
mean systemic fi lling pressure
mean systemic
pressure analog
venous return
circulatory filling pressure
central venous-pressure
cardiac-output
return curves
gradient
Physiology
Sport Sciences

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy