Intra- and inter-rater reliability of the Italian Fugl-Meyer assessment of upper and lower extremity
-
Hochleitner, I. (författare)
-
Pellicciari, L. (författare)
-
Castagnoli, C. (författare)
-
visa fler...
-
Paperini, A. (författare)
-
Politi, A. M. (författare)
-
Campagnini, S. (författare)
-
Pancani, S. (författare)
-
Basagni, B. (författare)
-
Gerli, F. (författare)
-
Carrozza, M. C. (författare)
-
Macchi, C. (författare)
-
- Alt Murphy, Margit, 1970 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience
-
Cecchi, F. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2022-08-27
- 2023
- Engelska.
-
Ingår i: Disability and Rehabilitation. - : Informa UK Limited. - 0963-8288 .- 1464-5165. ; 45:18, s. 2989-2999
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose To assess the intra- and inter-rater reliability motor and sensory functioning, balance, joint range of motion and joint pain subscales of the Italian Fugl-Meyer Assessment (FMA) Upper Extremity (FMA-UE) and Lower Extremity (FMA-LE) at the item- subtotal- and total-level in patients with sub-acute stroke. Materials and methods The FMA was administered to 60 patients with sub-acute stroke (mean age +/- SD = 75.4 +/- 10.7 years; 58.3% men) and independently rated by two physiotherapists on two consecutive days. Intra- and inter-reliability was studied by a rank-based statistical method for paired ordinal data to detect any systematic or random disagreement. Results The item-level intra- and inter-rater reliability was satisfactory (>70%). Reliability level >70% was achieved at subscale and total score level when one- or two-points difference was considered. Systematic disagreements were reported for five items of the FMA-UE, but not for FMA-LE. Conclusions The Italian version of the FMA showed to be a reliable instrument that can therefore be recommended for clinical and research purposes.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences (hsv//eng)
Nyckelord
- Reproducibility of results
- outcome assessment
- health care
- psychometrics
- physical therapy specialities
- rehabilitation
- outcome measures
- motor recovery
- upper-limb
- stroke
- intervention
- selection
- patient
- scale
- Rehabilitation
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Hochleitner, I.
-
Pellicciari, L.
-
Castagnoli, C.
-
Paperini, A.
-
Politi, A. M.
-
Campagnini, S.
-
visa fler...
-
Pancani, S.
-
Basagni, B.
-
Gerli, F.
-
Carrozza, M. C.
-
Macchi, C.
-
Alt Murphy, Marg ...
-
Cecchi, F.
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Hälsovetenskap
- Artiklar i publikationen
-
Disability and R ...
- Av lärosätet
-
Göteborgs universitet