SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/327374"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/327374" > Arterial occlusion ...

Arterial occlusion duration affects the cuff-induced hyperemic response in skeletal muscle BOLD perfusion imaging as shown in young healthy subjects

Arvidsson, Jonathan (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Eriksson, Stefanie (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Johansson, E. (författare)
visa fler...
Lagerstrand, Kerstin M (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Magnetic Resonance Materials in Physics Biology and Medicine. - 1352-8661. ; 36:6, s. 897-910
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective Dynamic BOLD MRI with cuff compression, inducing ischemia and post-occlusive hyperemia in skeletal mus-cle, has been pointed out as a potential diagnostic tool to assess peripheral limb perfusion. The objective was to explore the robustness of this technique and its sensitivity to the occlusion duration. Materials and methods BOLD images were acquired at 3 T in 14 healthy volunteers. T*2-imaging with 5-and 1.5-min occlu-sions were acquired and several semi-quantitative BOLD parameters were derived from ROI-based T*2-time curves. Differ-ences in parameters from the two different occlusion durations were evaluated in the gastrocnemius and soleus muscles using non-parametrical tests. Intra-and inter-scan repeatability were evaluated with coefficient of variation.Results Longer occlusion duration resulted in an increased hyperemic signal effect yielding significantly different values (p < 0.05) in gastrocnemius for all parameters describing the hyperemic response, and in soleus for two of these parameters. Specifically, 5-min occlusion yielded steeper hyperemic upslope in gastrocnemius (41.0%; p < 0.05) and soleus (59.7%; p = 0.03), shorter time to half peak in gastrocnemius (46.9%; p = 0.00008) and soleus (33.5%; p = 0.0003), and shorter time to peak in gastrocnemius (13.5%; p = 0.02). Coefficients of variation were lower than percentage differences that were found significant. Discussion Findings show that the occlusion duration indeed influences the hyperemic response and thus should play a part in future methodological developments.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

BOLD MRI
Semi-quantitative
T*2
Ischemia
Hyperemia
blood-oxygen level
calf muscles
reactive hyperemia
mri
ischemia
disease
Radiology
Nuclear Medicine & Medical Imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy