Quality of film-based and digital panoramic radiography.

Molander, Björn, 1949 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
Gröndahl, Hans-Göran, 1940 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
Ekestubbe, Annika, 1953 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
 (creator_code:org_t)
British Institute of Radiology, 2004
2004
Engelska.
Ingår i: Dento maxillo facial radiology. - : British Institute of Radiology. - 0250-832X. ; 33:1, s. 32-6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVES: To compare the image quality of panoramic radiographs obtained with storage phosphor plate and screen-film systems. METHODS: Panoramic radiographs were taken in 60 patients both with film and with a storage phosphor plate system (30 with DenOptix (Dentsply/Gendex) and 30 with Digora PCT). The images were obtained with either the Cranex Tome or the Scanora multimodal X-ray unit. The screen-film combination was Lanex medium/Curix Ortho HT-G. The digital images were displayed as 8-bit images with a 300 dpi resolution on a 19" monitor and the film images were placed on a light box adjacent to the screen. Ten observers evaluated diagnostic image quality by means of visual grading analysis of different anatomical structures. The structures were scored as being visualized much better (5), better (4), equal (3), worse (2) or much worse (1) in the digital images than in the film images. The mean number of patients receiving the different scores was calculated. Statistical methods used were Wilcoxon sign rank test and Mann-Whitney test. RESULTS: On average, visualization was equal in 19 of the 30 patients imaged using Digora PCT; in 10 it was worse. The corresponding values for DenOptix were 20 and 9. The difference between the film-based and the digital images was small but statistically significant (P<0.0001). The difference between the two image plate systems was not statistically significant (P>/=0.17). CONCLUSIONS: It was concluded that digital panoramic radiographs are equivalent to film-based images for most purposes.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Adult
Aged
Female
Humans
Image Processing
Computer-Assisted
standards
Male
Middle Aged
Observer Variation
Radiographic Image Enhancement
standards
Radiography
Dental
Digital
standards
Radiography
Panoramic
standards
Statistics
Nonparametric
X-Ray Film
standards
X-Ray Intensifying Screens
standards

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy