SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/67518"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/67518" > Relationship betwee...

Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability.

Meredith, N (författare)
Friberg, Bertil, 1950 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
Sennerby, Lars, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
visa fler...
Aparicio, Carlos (författare)
visa färre...
 (creator_code:org_t)
1998
1998
Engelska.
Ingår i: The International journal of prosthodontics. - 0893-2174. ; 11:3, s. 269-75
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: The Periotest is an electronic instrument that has been advocated for the measurement of implant stability and osseointegration. The aims of this investigation were to establish the relationship between contact time and PTV values when the Periotest was used to assess implants in vivo and in vitro, and to investigate the influence of the striking height of the Periotest handpiece and the length of implant abutment. MATERIALS AND METHODS: The accelerometer signal from a Periotest was captured and compared with the resulting PTV value. In vitro measurements of PTV and contract time were performed on a 3-mm abutment that had been attached to a 15-mm implant luted into an aluminium block, and were repeated on a patient in vivo. further measurements were made of the abutments of six implants in turn in the maxilla of the same patient. The standard abutment lengths on the implants were 3, 4 (x 2), 5.5 (x 2), and 7 mm. RESULTS: The results indicated that there was a linear relationship between contact time and PTV value for implants measured in vitro and in vivo. Greater scatter of the in vivo data was attributed to test and patient variables including striking position, distance, and damping as a result of the presence of soft tissue. There was a linear relationship between the PTV value and the striking height for implant measurements in vivo and in vitro. CONCLUSION: It can be concluded that the sensitivity of the Periotest to clinical variables including striking heights and handpiece angulation limit the application of the instrument as a clinical diagnostic aid to measure implant stability.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Dental Abutments
Dental Implants
Diagnosis
Oral
instrumentation
Equipment Design
Evaluation Studies as Topic
Humans
Materials Testing
Osseointegration
Percussion
Reproducibility of Results
Time Factors

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Meredith, N
Friberg, Bertil, ...
Sennerby, Lars, ...
Aparicio, Carlos
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
The Internationa ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy