Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits : A two-center study
-
- Bowyer, A. E. (författare)
- Sheffield Teaching Hospitals
-
- Hillarp, A. (författare)
- Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups,Skåne University Hospital
-
- Ezban, M. (författare)
- Novo Nordisk A/S
-
visa fler...
-
- Persson, P. (författare)
- Novo Nordisk A/S
-
- Kitchen, S. (författare)
- Sheffield Teaching Hospitals
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2016
- 2016
- Engelska.
-
Ingår i: Journal of Thrombosis and Haemostasis. - : Elsevier BV. - 1538-7933 .- 1538-7836. ; 14:7, s. 1428-1435
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Essentials: Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Summary: Background: Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives: To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods: FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL-1, to high, i.e. 0.90 IU mL-1) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results: A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions: These results suggest that, of the reagents tested, FIX:C in N9-GP-containing plasma samples can be most accurately measured with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Hematologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Hematology (hsv//eng)
Nyckelord
- Blood coagulation test
- Factor IX
- Hemophilia B
- Nonacog beta pegol
- Poly(ethylene glycol)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas