The role of breast tomosynthesis in a predominantly dense breast population at a tertiary breast centre : breast density assessment and diagnostic performance in comparison with MRI
-
- Förnvik, Daniel (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
-
- Kataoka, Masako (författare)
- Kyoto University
-
- Iima, Mami (författare)
- Kyoto University
-
visa fler...
-
- Ohashi, Akane (författare)
- Kyoto University
-
- Kanao, Shotaro (författare)
- Kyoto University
-
- Toi, Masakazu (författare)
- Kyoto University
-
- Togashi, Kaori (författare)
- Kyoto University
-
visa färre...
-
(creator_code:org_t)
- 2018-02-19
- 2018
- Engelska.
-
Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 28:8, s. 3194-3203
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://europepmc.or...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objectives: To compare breast density measured on digital breast tomosynthesis (DBT) (BI-RADS-based breast composition and fully-automatic estimation) and magnetic resonance imaging (MRI) (BI-RADS amount of fibroglandular tissue), and to evaluate the diagnostic performance in terms of sensitivity and specificity of DBT and MRI in a predominantly dense breast population. Methods: Between 2015 and 2016, 152 women with 103 breast malignancies, who underwent 3-T breast MRI and DBT within 2 months’ time, were enrolled in this study. Breast composition/fibroglandular tissue and findings on DBT (two readers) and MRI were reported using BI-RADS 5th edition. Digital mammography images were analysed for breast percent density (PD) using the Libra software tool. Results: A majority of women had dense breasts as categorised by breast composition c (heterogeneously dense) (68%) and d (extremely dense) (15%). The mean PD was 44% (range, 18-89%) and the correlation between breast composition and PD was r = 0.6. The diagnostic performance of MRI was significantly higher compared to DBT for one reader as described by the area under the receiver operating characteristic (ROC) curve (p = 0.004) and of borderline significance for the other reader (p = 0.052). Conclusions: MRI had higher diagnostic performance than DBT in a dense breast population in the tertiary setting. Key Points: • MRI had higher diagnostic performance than DBT in a dense breast population• Diagnostic performance of DBT was comparable to MRI in women with fatty breasts• MRI was superior to DBT in preoperative breast cancer size assessment
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Breast cancer
- Breast density
- Diagnostic techniques and procedures
- Digital breast tomosynthesis
- Magnetic resonance imaging
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)