Reproducibility of ultrasonic fetal volume blood flow measurements

Brodszki, Jana (författare)
Lund University,Lunds universitet,Obstetrik och gynekologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Obstetrics and Gynaecology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Gardiner, H M (författare)
Eriksson, A (författare)
visa fler...
Stale, Håkan (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
Marsal, Karel (författare)
Lund University,Lunds universitet,Obstetrik och gynekologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Obstetrics and Gynaecology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2002-01-04
1998
Engelska.
Ingår i: Clinical Physiology. - : Wiley. - 1365-2281 .- 0144-5979. ; 18:5, s. 479-485
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The intraobserver reproducibility of ultrasonic volume blood flow measurements in the human fetus was evaluated in this study. A new approach, simultaneous measurement of the vessel diameter and the flow velocity with a pulsed-wave Doppler ultrasound synchronized with a real-time ultrasound phase-locked echo-tracking system, was used to estimate volume blood flow (VBF) in the fetal descending aorta. Measurements were performed in a longitudinal study on 20 normally grown fetuses. Intraobserver reproducibility of repeated estimations of mean blood flow velocities throughout gestation was very good, with high values of intraclass correlation coefficient (IntraCC 0.80-0.91) and low values of coefficient of variation (CV 4-11%). The IntraCC of repeated vessel diameter measurements throughout gestation was low (0.30-0.68), whereas the values of CV were acceptable (< 12%), with the exception of the period between 140 and 167 gestational days (CV > 12%). The lower reproducibility of vessel diameter measurement contributed directly to the relatively low reproducibility of VBF estimations overall (IntraCC 0.25-0.70; CV 17-28%), as these are calculated from a formula using both flow velocity and vessel diameter. Nevertheless, the synchronized approach gives absolute values of vessel diameter, flow velocity and VBF comparable with values reported in the human fetus previously. The new method provides, by taking the vessel wall pulsations into consideration and by measuring diameter and velocity simultaneously, a more complete information on fetal haemodynamics and fetal physiology.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)

Nyckelord

Doppler ultrasound
fetal blood flow
intraobserver agreement
ultrasound
velocity
vessel diameter

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Brodszki, Jana
Gardiner, H M
Eriksson, A
Stale, Håkan
Marsal, Karel
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Reproduktionsmed ...
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy