Sökning: onr:"swepub:oai:lup.lub.lu.se:0a58a3d9-8606-4e4c-9859-5bb29ba2c8b2" >
Discrepancies betwe...
Discrepancies between the one-stage clotting assay and the chromogenic assay in haemophilia B
-
- Kihlberg, K. (författare)
- Skåne University Hospital
-
- Strandberg, K. (författare)
- Skåne University Hospital
-
Rosén, S. (författare)
-
visa fler...
-
- Ljung, R. (författare)
- Lund University,Lunds universitet,Pediatrik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Pediatrisk hematologi,Forskargrupper vid Lunds universitet,Paediatrics (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Paediatric Haematology Research Unit,Lund University Research Groups,Skåne University Hospital
-
- Astermark, J. (författare)
- Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- 2017-04-24
- 2017
- Engelska.
-
Ingår i: Haemophilia. - : Wiley. - 1351-8216. ; 23:4, s. 620-627
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Introduction: Assay discrepancy in factor VIII activity between the one-stage and the chromogenic assays has been described in approximately one third of patients with non-severe haemophilia A. Whether assay discrepancy may also occur in patients with haemophilia B remains unknown. Aim: This study compared the results from the one-stage and the chromogenic assays in patients with haemophilia B. Methods: Plasma samples from patients with haemophilia B attending the haemophilia centre in Malmö, Sweden, were collected after a wash-out period of more than 7 days and analysed with both assays. Results: Fifty samples from 36 patients were analysed. No discrepancy was found in patients with severe haemophilia B. Among the 44 plasma samples from patients with non-severe disease, 15 showed a twofold or greater difference between the results of the two methods, with the chromogenic method presenting the higher value (mean FIX:Cone-stage 0.02 vs. FIX:Cchromo 0.06 IU mL-1). Of these 15 samples, 14 were from seven individuals from five families with the same mutated amino acid at the N-terminal cleaving site of the activation peptide (FIX: c.572G>A; p.Arg191His or FIX: c.571C>T; p.Arg191Cys). These mutations were not observed in any patients with non-discrepant results. The reported bleeding frequency for these patients was low and indicative of a mild bleeding phenotype. Conclusion: Our findings imply that assay discrepancy occurs for factor IX activity and that both type of assays are needed for a correct diagnosis and classification of haemophilia B. The underlying mechanism by which the mutation influences the assays remains to be determined.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Hematologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Hematology (hsv//eng)
Nyckelord
- Assay discrepancy
- Chromogenic assay
- Coagulation factor IX
- Haemophilia B
- Mutations
- One-stage assay
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas