High-level energy estimation in the sub-VT domain: simulation and measurement of a cardiac event detector
-
- Akgun, OmerCan (författare)
- Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
-
- Rodrigues, Joachim (författare)
- Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
-
Leblebici, Yusuf (författare)
-
visa fler...
-
- Öwall, Viktor (författare)
- Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2012
- 2012
- Engelska.
-
Ingår i: IEEE Transactions on Biomedical Circuits and Systems. - 1932-4545. ; 6:1, s. 15-27
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- This paper presents a flow that is suitable to estimate energy dissipation of digital standard-cell based designs which are determined to be operated in the sub-threshold regime. The flow is applicable on gate-level netlists, where back-annotated toggle information is used to find the minimum energy operation point, corresponding maximum clock frequency, as well as the dissipated energy per clock cycle. The application of the model is demonstrated by exploring the energy efficiency of pipelining, retiming and register balancing. Simulation results, which are obtained during a fraction of SPICE simulation time, are validated by measurements on a wavelet based cardiac event detector that was fabricated in 65 nm low-leakage high-threshold technology. The mean of the absolute modeling error is calculated as 5.2 %, with a standard deviation of 6.6% over the measurement points. The cardiac event detector dissipates 0.88 pJ/sample at a supply voltage of 320mV.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
Nyckelord
- High-level energy estimation
- sub-threshold
- QRS detection
- R-wave
- cardiac pacemaker
- energy model.