High-level energy estimation in the sub-VT domain: simulation and measurement of a cardiac event detector

Akgun, OmerCan (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
Rodrigues, Joachim (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
Leblebici, Yusuf (författare)
visa fler...
Öwall, Viktor (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: IEEE Transactions on Biomedical Circuits and Systems. - 1932-4545. ; 6:1, s. 15-27
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents a flow that is suitable to estimate energy dissipation of digital standard-cell based designs which are determined to be operated in the sub-threshold regime. The flow is applicable on gate-level netlists, where back-annotated toggle information is used to find the minimum energy operation point, corresponding maximum clock frequency, as well as the dissipated energy per clock cycle. The application of the model is demonstrated by exploring the energy efficiency of pipelining, retiming and register balancing. Simulation results, which are obtained during a fraction of SPICE simulation time, are validated by measurements on a wavelet based cardiac event detector that was fabricated in 65 nm low-leakage high-threshold technology. The mean of the absolute modeling error is calculated as 5.2 %, with a standard deviation of 6.6% over the measurement points. The cardiac event detector dissipates 0.88 pJ/sample at a supply voltage of 320mV.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

High-level energy estimation
sub-threshold
QRS detection
R-wave
cardiac pacemaker
energy model.

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Akgun, OmerCan
Rodrigues, Joach ...
Leblebici, Yusuf
Öwall, Viktor
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
Artiklar i publikationen
IEEE Transaction ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy