Sökning: onr:"swepub:oai:lup.lub.lu.se:1203305c-fc79-41bd-9a34-3222a4b198a4" >
Optical projection ...
Optical projection tomography for rapid whole mouse brain imaging
-
- Nguyen, David (författare)
- Swiss Federal Institute of Technology
-
- Marchand, Paul J. (författare)
- Swiss Federal Institute of Technology
-
- Planchette, Arielle L. (författare)
- Swiss Federal Institute of Technology
-
visa fler...
-
- Nilsson, Julia (författare)
- Lund University,Lunds universitet,Autoimmunitet,Forskargrupper vid Lunds universitet,Autoimmunity,Lund University Research Groups
-
- Sison, Miguel (författare)
- Swiss Federal Institute of Technology
-
- Extermann, Jérôme (författare)
- Swiss Federal Institute of Technology
-
- Lopez, Antonio (författare)
- Swiss Federal Institute of Technology
-
- Sylwestrzak, Marcin (författare)
- Swiss Federal Institute of Technology
-
- Sordet-Dessimoz, Jessica (författare)
- Swiss Federal Institute of Technology
-
- Schmidt-Christensen, Anja (författare)
- Lund University,Lunds universitet,Autoimmunitet,Forskargrupper vid Lunds universitet,Autoimmunity,Lund University Research Groups
-
- Holmberg, Dan (författare)
- Lund University,Lunds universitet,Autoimmunitet,Forskargrupper vid Lunds universitet,Autoimmunity,Lund University Research Groups
-
- Van De Ville, Dimitri (författare)
- Swiss Federal Institute of Technology
-
- Lasser, Theo (författare)
- Swiss Federal Institute of Technology
-
visa färre...
-
(creator_code:org_t)
- 2017
- 2017
- Engelska 14 s.
-
Ingår i: Biomedical Optics Express. - 2156-7085. ; 8:12, s. 5637-5650
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- In recent years, three-dimensional mesoscopic imaging has gained significant importance in life sciences for fundamental studies at the whole-organ level. In this manuscript, we present an optical projection tomography (OPT) method designed for imaging of the intact mouse brain. The system features an isotropic resolution of ~50 µm and an acquisition time of four to eight minutes, using a 3-day optimized clearing protocol. Imaging of the brain autofluorescence in 3D reveals details of the neuroanatomy, while the use of fluorescent labels displays the vascular network and amyloid deposition in 5xFAD mice, an important model of Alzheimer’s disease (AD). Finally, the OPT images are compared with histological slices.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Nguyen, David
-
Marchand, Paul J ...
-
Planchette, Arie ...
-
Nilsson, Julia
-
Sison, Miguel
-
Extermann, Jérôm ...
-
visa fler...
-
Lopez, Antonio
-
Sylwestrzak, Mar ...
-
Sordet-Dessimoz, ...
-
Schmidt-Christen ...
-
Holmberg, Dan
-
Van De Ville, Di ...
-
Lasser, Theo
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Biomedical Optic ...
- Av lärosätet
-
Lunds universitet