Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography.

Svahn, T M (författare)
Houssami, N (författare)
Sechopoulos, I (författare)
visa fler...
Mattsson, Sören (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Breast. - : Elsevier BV. - 1532-3080. ; 24:2, s. 93-99
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • We examined how radiation dose levels in digital breast tomosynthesis (DBT) differ from those used in 2-view full-field digital mammography (FFDM). Acquisition parameter settings and information on the average absorbed dose to the glandular tissues within the breasts were reviewed based on clinical studies that evaluated DBT and FFDM. Dose ratios (DDBT/DFFDM) were derived from imaging protocols, which included tomosynthesis in 1- or 2-views alone, and as an adjunct technique to FFDM. Stand-alone DBT was associated with a much lower to a slightly higher radiation dose compared to that of comparable FFDM units, as summarized in dose ratio ranges of 0.34-1.0 for 1-view DBT, and 0.68-1.17 for 2-view DBT. One of the lowest reported dose estimates was obtained using a photon-counting DBT unit (avg. 0.70 mGy/scan; range: 0.28-1.26 mGy). Breast doses for DBT combined with FFDM are summarized in dose ratio ranges of 1.03-1.5 for 1-view DBT plus FFDM, and 2.0-2.23 for 2-view DBT plus FFDM. In the latter of these settings, the dose was reduced by ∼45% when 2D-views, reconstructed from the DBT images ("synthetic 2D images"), were used as a substitute for FFDM. Stand-alone DBT operated at lower to slightly higher radiation doses in comparison to FFDM. For DBT combined with FFDM, radiation doses were elevated, at maximum by a factor ∼2 1/4 of that of FFDM alone. In this setting, a replacement of FFDM with synthetic 2D-views reduced the breast dose approximately by half, which has substantial implications for population screening programs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Publikations- och innehållstyp

for (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Breast (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Svahn, T M
Houssami, N
Sechopoulos, I
Mattsson, Sören
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Cancer och onkol ...
Artiklar i publikationen
Breast
The Breast
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy