Sökning: onr:"swepub:oai:lup.lub.lu.se:176a1163-ed24-430e-9a76-39f622e64595" >
Determination of 21...
Determination of 21-hydroxylase autoantibodies: inter-laboratory concordance in the Euradrenal International Serum Exchange Program
-
- Falorni, Alberto (författare)
- Univ Perugia, Dept Med, I-06126 Perugia, Italy.
-
- Bini, Vittorio (författare)
- Univ Perugia, Dept Med, I-06126 Perugia, Italy.
-
- Betterle, Corrado (författare)
- Univ Padua, Dept Med, Endocrine Unit, Padua, Italy.
-
visa fler...
-
- Brozzetti, Annalisa (författare)
- Univ Perugia, Dept Med, I-06126 Perugia, Italy.
-
- Castano, Luis (författare)
- Univ Basque Country, Cruces Univ Hosp, Ciberdem, BioCruces, Bilbao, Spain.
-
- Fichna, Marta (författare)
- Poznan Univ Med Sci, Dept Endocrinol & Metab, Poznan, Poland.;Polish Acad Sci, Inst Human Genet, PL-60479 Poznan, Poland.
-
- Kämpe, Olle (författare)
- Karolinska Institutet,Uppsala universitet,Autoimmunitet,Science for Life Laboratory, SciLifeLab
-
- Mellgren, Gunnar (författare)
- Haukeland Hosp, Hormone Lab, N-5021 Bergen, Norway.;Univ Bergen, Dept Clin Sci, Bergen, Norway.
-
- Peterson, Part (författare)
- Univ Tartu, Inst Biomed & Translat Med, Mol Pathol, EE-50090 Tartu, Estonia.
-
- Chen, Shu (författare)
- RSR Ltd, FIRS Labs, Cardiff, S Glam, Wales.
-
- Rönnelid, Johan (författare)
- Uppsala universitet,Klinisk immunologi
-
- Seissler, Jochen (författare)
- Klinikum Univ Munchen, Med Klin & Poliklin 4, Diabet Zentrum, Munich, Germany.
-
- Tiberti, Claudio (författare)
- Univ Roma La Sapienza, Dept Expt Med, I-00185 Rome, Italy.
-
- Uibo, Raivo (författare)
- Univ Tartu, Inst Biomed & Translat Med, Dept Immunol, EE-50090 Tartu, Estonia.
-
- Yu, Liping (författare)
- Univ Colorado Denver, Barbara Davis Ctr Diabet, Aurora, CO USA.
-
- Lernmark, Åke (författare)
- Lund University,Lunds universitet,Celiaki och diabetes,Forskargrupper vid Lunds universitet,Celiac Disease and Diabetes Unit,Lund University Research Groups,Lund Univ, Skane Univ Hosp, Dept Clin Sci, Malmo, Sweden.
-
- Husebye, Eystein (författare)
- Univ Bergen, Dept Clin Sci, Bergen, Norway.;Haukeland Hosp, Dept Med, N-5021 Bergen, Norway.
-
visa färre...
-
Univ Perugia, Dept Med, I-06126 Perugia, Italy Univ Padua, Dept Med, Endocrine Unit, Padua, Italy. (creator_code:org_t)
- Walter de Gruyter GmbH, 2015
- 2015
- Engelska.
-
Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 53:11, s. 1761-1770
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: 21-Hydroxylase autoantibodies (21OHAb) are markers of an adrenal autoimmune process that identifies individuals with autoimmune Addison's disease (AAD). Quality and inter-laboratory agreement of various 21OHAb tests are incompletely known. The objective of the study was to determine inter-laboratory concordance for 21OHAb determinations. Methods: Sixty-nine sera from 51 patients with AAD and 51 sera from 51 healthy subjects were blindly coded by a randomization center and distributed to 14 laboratories that determined 21OHAb, either by an "in-house" assay (n=9) using in vitro-translated S-35-21OH or luciferase-labeled 21OH or a commercial kit with I-125-21OH (n=5). Main outcome measures were diagnostic accuracy of each participating laboratory and inter-laboratory agreement of 21OHAb assays. Results: Intra-assay coefficient of variation ranged from 2.6% to 5.3% for laboratories using the commercial kit and from 5.1% to 23% for laboratories using "in-house" assays. Diagnostic accuracy, expressed as area under ROC curve (AUC), varied from 0.625 to 0.947 with the commercial kit and from 0.562 to 0.978 with "in-house" methods. Cohen's. of inter-rater agreement was 0.603 among all 14 laboratories, 0.691 among "in-house" laboratories, and 0.502 among commercial kit users. Optimized cutoff levels, calculated on the basis of AUCs, increased the diagnostic accuracy of every laboratory (AUC >0.9 for 11/14 laboratories) and increased the Cohen's. of inter-rater agreement. Discrepancies in quantitation of 21OHAb levels among different laboratories increased with increasing autoantibody levels. Conclusions: The quality of 21OHAb analytical procedures is mainly influenced by selection of cutoff value and correct handling of assay materials. A standardization program is needed to identify common standard sera and common measuring units.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Immunologi inom det medicinska området (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Immunology in the medical area (hsv//eng)
Nyckelord
- Addison's disease
- adrenal antibodies
- autoimmunity
- diagnosis
- RIA
- standardization
- Addison's disease
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Falorni, Alberto
-
Bini, Vittorio
-
Betterle, Corrad ...
-
Brozzetti, Annal ...
-
Castano, Luis
-
Fichna, Marta
-
visa fler...
-
Kämpe, Olle
-
Mellgren, Gunnar
-
Peterson, Part
-
Chen, Shu
-
Rönnelid, Johan
-
Seissler, Jochen
-
Tiberti, Claudio
-
Uibo, Raivo
-
Yu, Liping
-
Lernmark, Åke
-
Husebye, Eystein
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Reumatologi och ...
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Medicinska och f ...
-
och Immunologi inom ...
- Artiklar i publikationen
-
Clinical Chemist ...
- Av lärosätet
-
Lunds universitet
-
Uppsala universitet
-
Karolinska Institutet