SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:19a01905-467e-4038-9f5f-12231e9def3f"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:19a01905-467e-4038-9f5f-12231e9def3f" > Internal Dosimetry ...

Internal Dosimetry Development and Evaluation of Methods and Models

Jönsson, Lena M (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
ISBN 9789162870904
2007
Engelska 52 s.
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Radionuclide therapy requires patient-specific planning of the absorbed dose to target volumes, in most cases tumours, in order to achieve an expected biological effect, taking into account that the absorbed doses to normal organs and tissues should be kept as low as reasonably achievable. Therefore, the calculation of absorbed doses has to be as accurate as possible. The accuracy depends on the methods used for activity quantification and on how well the dosimetric model describes the organs and tissues in the particular patient. This thesis presents new methodologies developed to investigate the accuracy of internal dosimetry. The main focus was on the use of detailed biokinetic data from animals combined with Monte Carlo simulations using anthropomorphic phantoms on macro level, and applied in the development and refinement of an intestinal dosimetry model on a small-scale level. A novel approach is the generation of Monte Carlo simulated scintillation camera images of a computer patient using a radionuclide biodistribution obtained from an experimental animal study. The accuracy of the activity quantification based on planar scintillation camera imaging was investigated and in particular the corrections for attenuation and scatter with the presence of activity in overlapping tissues. The absorbed doses were calculated using phantom-specific dose factors (S values) and were compared with absorbed doses calculated from standard MIRD-phantom-based S values. The results demonstrate the potential inaccuracy of the calculated absorbed dose to an individual patient when using dose factors based on the MIRD phantom. A dosimetry model for the small intestine was developed and refined in order to obtain a more accurate model and dose factors. Previous dosimetry models of the small intestine have been limited to calculating the absorbed dose to the intestinal wall from activity in the contents only. The work in this thesis included Monte Carlo calculations of dose factors for the radiation sensitive crypt cells as target organ. The activity in the contents as well as in the intestinal wall was taken into account, and dose factors were calculated for both self-dose and cross-dose from surrounding parts of the small intestine. Calculations of the absorbed dose to the crypt cells for a realistic activity distribution are presented and compared with results from the general absorbed dose calculation. It is evident from the results in this thesis that improvements are necessary in the quantification procedure, as well as further development of more realistic, small-scale anatomy models.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

tomografi
Klinisk fysiologi
medical instrumentation
tomography
radiology
Clinical physics
crypt cells
intestine
radionuclide
scintillation camera
sestamibi
activity quantification
conjugate view method
Monte Carlo simulation
internal dosimetry
Nuclear medicine
radiobiology
Nukleärmedicin
radiobiologi
medicinsk instrumentering
radiologi

Publikations- och innehållstyp

dok (ämneskategori)
vet (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jönsson, Lena M
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy