Porous silicon as a potential electrode material in a nerve repair setting: Tissue reactions.
-
- Johansson, Fredrik (författare)
- Lund University,Lunds universitet,Biologiska institutionen,Naturvetenskapliga fakulteten,Department of Biology,Faculty of Science
-
- Wallman, Lars (författare)
- Lund University,Lunds universitet,Neurofysiologi,Forskargrupper vid Lunds universitet,Neurophysiology,Lund University Research Groups
-
- Danielsen, Nils (författare)
- Lund University,Lunds universitet,Neurala gränsytor,Forskargrupper vid Lunds universitet,Neural Interfaces,Lund University Research Groups
-
visa fler...
-
- Schouenborg, Jens (författare)
- Lund University,Lunds universitet,Neurofysiologi,Forskargrupper vid Lunds universitet,Neurophysiology,Lund University Research Groups
-
- Kanje, Martin (författare)
- Lund University,Lunds universitet,Funktionell zoologi,Biologiska institutionen,Naturvetenskapliga fakulteten,Functional zoology,Department of Biology,Faculty of Science
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2009
- 2009
- Engelska.
-
Ingår i: Acta Biomaterialia. - : Elsevier BV. - 1878-7568 .- 1742-7061. ; 5, s. 2230-2237
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- We compared porous silicon (pSi) with smooth Si as chip-implant surfaces in a nerve regeneration setting. Silicon chips can be used for recording neural activity and are potential nerve interface devices. A silicon chip with one smooth and one porous side inserted into a tube was used to bridge a 5 mm defect in rat sciatic nerve. Six or 12 weeks later, new nerve structures surrounded by a perineurium-like capsule had formed on each side of the chip. The number of regenerated nerve fibers did not differ on either side of the chip as shown by immunostaining for neurofilaments. However, the capsule that had formed in contact with the chip was significantly thinner on the porous side than on the smooth side. Cellular protrusions had formed on the pSi side and the regenerated nerve tissue was found to attach firmly to this surface, while the tissue was hardly attached to the smooth silicon surface. We conclude that a pSi surface, due to its large surface area, diminished inflammatory response and firm adhesion to the tissue, should be a good material for the development of new implantable electronic nerve devices.